OSHA Inspection: SYLVIN TECHNOLOGIES, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SYLVIN TECHNOLOGIES, INCORPORATED in DENVER ROAD, DENVER, PA 17517 (NAICS 325211). OSHA activity number 308476456.

Watch Sylvin Technologies, Incorporated — free Get an email when a new federal OSHA severe-injury report for Sylvin Technologies, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
DENVER ROAD
City
DENVER
State
PA
ZIP
17517
Mailing
DENVER ROAD, P.O. BOX 308, DENVER, PA 17517
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
35
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 3 instances 25 exposed
Issued
Abate by
Penalty
Initial $875.00 · Current $300.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm in that employees were exposed to the
hazard of potential fire and explosion
because methods and practices were not utilized to protect air/material
separators (dust collectors) from
explosion and prevent propagation of fire/explosion from air/material
separators (dust collectors) into areas
occupied by employees:
(a)Line 1 Torit Dust Collector and Line 2 Scientific Collection Dust
Collector - Deflagration
venting was not provided to minimize the pressures developed in the event
of fire or explosion
within the dust collectors, on or about June 7, 2006.
(b)Line 1 Torit Dust Collector and Line 2 Scientific Collection Dust
Collector - Isolation devices
such as back-draft dampers were not utilized to prevent deflagrations
(fire/explosion) from
traveling through duct-work to charging and mixing stations occupied by
employees,
on or
about June 7, 2006.
(c)Line 2 Scientific Collection Dust Collector - Exhaust air was not
discharged to a restricted area
in that the discharge to the Line 2 Dust collector was located adjacent to
a designated outside
break area for employees, on or about June 7, 2006.
ABATEMENT NOTE:  Among other methods, one feasible and acceptable
abatement method to
correct these hazards is to comply with the National Fire Protection
Agency (NFPA) 654, "Standard
for the Prevention of Fire and Dust Explosions from the Manufacturing,
Processing, and Handling of
Combustible Particulate Solids" (2006) as it applies to your operations
and equipment including but not
limited to:
Protect dust collectors in accordance with Section 7.13.1.3 or otherwise
adhere to the
exceptions as listed.
Provide isolation devices in accordance with Section 7.13.1.5 or otherwise
adhere
to the
exceptions as listed.
Discharge exhaust air to a safe area in accordance with Section 7.13.1.7
or otherwise adhere
to the exceptions as listed.
VERIFICATION REQUIRED
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $875.00

1910.22 A01

Serious Gravity 03 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $875.00 · Current $300.00 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $875.00

1910.157 G03

Other-than-serious Gravity 01 1 instance 25 exposed
Issued
Abate by

View SYLVIN TECHNOLOGIES, INCORPORATED's full OSHA safety record →