Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEMART CONTRACTING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JEMART CONTRACTING, INC. in STORE COMPLEX 451 MAIN ST., LITTLE FALLS, NJ 07424 (NAICS 236210). OSHA activity number 308616283.

Watch Jemart Contracting, INC. — free Get an email when a new federal OSHA severe-injury report for Jemart Contracting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
STORE COMPLEX 451 MAIN ST.
City
LITTLE FALLS
State
NJ
ZIP
07424
Mailing
207 EILEEN DR, CEDAR GROVE, NJ 07009
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
SIC code (legacy)
1541
Employees
3
Ownership type
A
Industry flags
Construction safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $400.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees
in that employees
were exposed to possible blunt injuries and being sgruck by falling
objects:
a) On site: Employees engaged in setting wood trusses on a new
building under construction were exposed to the hazards associated
with truss collapse due to the removal of truss bracing, on or about
June 20, 2005.
Note: Feasible means of abatement that can be used to correct this
include: Installing the
trusses in accordance with guidance provided by the Wood Truss Council of
America and
Truss Plate Institute, Building Component Safety Information, BCSI-1-03,
"Guide to
Good Practice For Handling, Installing and Bracing of Metal Plate
Connected Wood
Trusses, published Oct 1, 2003, effective 01/01/04 which states:
"Temporary erection
bracing must be applied to three planes of the roof system to ensure
stability: Plane 1)
Top Chord (sheathing), Plane 2) Bottom Chord (ceiling plane), and Plane 3)
Web
Member plane vertical plane perpendicular to trusses." For trusses longer
than 60 feet,
"consult a Registered Professional Engineer to calculate the ground brace
locations and
top chord bracing."
Recent events (2)
  • — I (S) $400.00
  • — Z (S) $600.00

1926.21 B02

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by

1926.100 A

Serious Gravity 03 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $500.00 Reduced
Recent events (2)
  • — I (S) $500.00
  • — Z (S) $750.00

1926.251 A01

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00
Recent events (2)
  • — I (S)
  • — Z (S) $600.00

1926.1053 B04

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $400.00 Reduced
Recent events (2)
  • — I (S) $400.00
  • — Z (S) $600.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308616283.