LITTLE FALLS, NJ —
OSHA Inspection: JEMART CONTRACTING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JEMART CONTRACTING, INC. in STORE COMPLEX 451 MAIN ST., LITTLE FALLS, NJ 07424 (NAICS 236210). OSHA activity number 308616283.
Where did this inspection happen?
- Establishment
- JEMART CONTRACTING, INC.
- Site address
- STORE COMPLEX 451 MAIN ST.
- City
- LITTLE FALLS
- State
- NJ
- ZIP
- 07424
- Mailing
- 207 EILEEN DR, CEDAR GROVE, NJ 07009
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- SIC code (legacy)
- 1541
- Employees
- 3
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $400.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to possible blunt injuries and being sgruck by falling objects: a) On site: Employees engaged in setting wood trusses on a new building under construction were exposed to the hazards associated with truss collapse due to the removal of truss bracing, on or about June 20, 2005. Note: Feasible means of abatement that can be used to correct this include: Installing the trusses in accordance with guidance provided by the Wood Truss Council of America and Truss Plate Institute, Building Component Safety Information, BCSI-1-03, "Guide to Good Practice For Handling, Installing and Bracing of Metal Plate Connected Wood Trusses, published Oct 1, 2003, effective 01/01/04 which states: "Temporary erection bracing must be applied to three planes of the roof system to ensure stability: Plane 1) Top Chord (sheathing), Plane 2) Bottom Chord (ceiling plane), and Plane 3) Web Member plane vertical plane perpendicular to trusses." For trusses longer than 60 feet, "consult a Registered Professional Engineer to calculate the ground brace locations and top chord bracing."
Recent events (2)
- — I (S) $400.00
- — Z (S) $600.00
1926.21 B02
- Issued
- Abate by
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $750.00 · Current $500.00 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $750.00
1926.251 A01
- Issued
- Abate by
- Penalty
- Initial $600.00
Recent events (2)
- — I (S)
- — Z (S) $600.00
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $400.00 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $600.00
More inspections in this industry (NAICS 236210)
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
WOODBINE, KY—2026-07-07
69283 - CONGLETON HACKER COMPANY
SHAMOKIN DAM, PA—2026-07-06
WATSON EXCAVATING, INC.
LONG BEACH, CA—2026-07-03
CAVALLI, INC.
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 308616283.