WICHITA, KS —
OSHA Inspection: CENTRAL POWER SYSTEMS AND SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CENTRAL POWER SYSTEMS AND SERVICES in 4501 IRVING ST., WICHITA, KS 67209 (NAICS 811310). OSHA activity number 308644376.
Where did this inspection happen?
- Establishment
- CENTRAL POWER SYSTEMS AND SERVICES
- Site address
- 4501 IRVING ST.
- City
- WICHITA
- State
- KS
- ZIP
- 67209
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- SIC code (legacy)
- 7699
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $3150.00 · Current $1575.00 Reduced
General-duty citation text
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards: Mechanic Shop - Employees were exposed to electrical hazards caused by the Sefac yellow automobile lift, Series #1200 M.5, which was not functioning properly. The handle/knob of the master control box at the main switch for the lift was completely broken off. Service Area Mechanics were opening the cover and using a pair of pliers and/or a screwdriver to engage and disengage the ON/OFF switch. The lift was not inspected on a periodic basis and subsequently not taken out of service until electrical repairs had been completed. Among other methods, one feasible and acceptable method to correct this hazard is to establish and enforce periodic inspection procedures in accordance with ANSI B153.1 1990, Section 7.3, "American National Standard for Automobile Lifts Safety Requirements for the Construction, Care, and Use". 29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is completed.
Recent events (2)
- — I (S) $1575.00
- — Z (S) $3150.00
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $1350.00 · Current $675.00 Reduced
Recent events (2)
- — I (O) $675.00
- — Z (S) $1350.00
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $1350.00 · Current $1350.00
Recent events (2)
- — I (S) $1350.00
- — Z (S) $1350.00
More inspections in this industry (NAICS 811310)
CHRISTIANSBURG, VA—2026-07-09
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08
TAYLOR BUILT PRODUCTS
, AK—2026-07-08
ANGUS ENTERPRISES
LOS ANGELES, CA—2026-07-08
CHILLEST INDUSTRIES LLC
More inspections in KS
WICHITA, KS—2026-07-10
DIVERSIFIED SERVICES, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
WICHITA, KS—2026-07-09
FIGEAC AERO NORTH AMERICA, INC.
PITTSBURG, KS—2026-07-08
CDL ELECTRIC
WICHITA, KS—2026-07-08
IBT, INC
Source