POSEN, IL —
OSHA Inspection: BERKSHIRE REFRIGERATED WAREHOUSING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BERKSHIRE REFRIGERATED WAREHOUSING, LLC in 2525 WEST 139TH PLACE, POSEN, IL 60469 (NAICS 493120). OSHA activity number 309030633.
Where did this inspection happen?
- Establishment
- BERKSHIRE REFRIGERATED WAREHOUSING, LLC
- Site address
- 2525 WEST 139TH PLACE
- City
- POSEN
- State
- IL
- ZIP
- 60469
- Mailing
- 4550 SOUTH PACKER AVENUE, CHICAGO, IL 60609
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- SIC code (legacy)
- 4222
- Employees
- 5
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $750.00 · Current $525.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational safety and Health Act of 1970: the employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: Engine Room - On or about May 3, 2006, employee(s) were exposed to hazards arising from the employer's non-compliance with the prescribed safeguards of the ANSI/ASHRAE Standard (2004), "Safety Standard for Refrigeration Systems", or of an equivalent, and generally accepted standard. Specifically: a. Doors were not clearly marked or permanent signs posted with "ONLY AUTHORIZED ENTRY" at doors of engine room. b. No signs on vessels as per NFPA or HMIS. c. Valves and piping in ammonia service not identified or labeled. d. All pipes piercing the interior walls were not tightly sealed to the walls through which they pass. e. No visual alarm located outside each entrance of the refrigerating machinery room. f. No outside emergency stop. g. Doors communicating to engine room were not self-closing, tight-fitting, and opening outward. h. Walls and doors of engine room were not of at least one-hour fire resistive construction.
Recent events (2)
- — I (S) $525.00
- — Z (S) $750.00
More inspections at BERKSHIRE REFRIGERATED WAREHOUSING, LLC
CHICAGO, IL—2026-01-15
BERKSHIRE REFRIGERATED WAREHOUSING, LLC
CHICAGO, IL—2019-08-08 00:00:00
BERKSHIRE REFRIGERATED WAREHOUSING, LLC
POSEN, IL—2005-11-02 00:00:00
BERKSHIRE REFRIGERATED WAREHOUSING, LLC
View BERKSHIRE REFRIGERATED WAREHOUSING, LLC's full OSHA safety record →
More inspections in this industry (NAICS 493120)
BIGLERVILLE, PA—2026-07-10
BREAM BEAR ORCHARDS
BIGLERVILLE, PA—2026-07-10
BREAM BEAR ORCHARDS
PLANT CITY, FL—2026-07-01
AMERICOLD LOGISTICS, LLC.
KELLER, TX—2026-07-01
KROGER TEXAS L.P.
SWEDESBORO, NJ—2026-07-01
GREENYARD LOGISTICS USA, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309030633.