APPLETON, WI —
OSHA Inspection: JOE DENOBLE WATER AND SEWER CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOE DENOBLE WATER AND SEWER CONSTRUCTION, INC. in PLANK & TAHOE, APPLETON, WI 54915 (NAICS 237110). OSHA activity number 309834349.
Where did this inspection happen?
- Establishment
- JOE DENOBLE WATER AND SEWER CONSTRUCTION, INC.
- Site address
- PLANK & TAHOE
- City
- APPLETON
- State
- WI
- ZIP
- 54915
- Mailing
- 4773 PODLASIK LN., DENMARK, WI 54208
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- SIC code (legacy)
- 1623
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards associated with working in confined spaces, such as sewer manholes approximately 13 feet deep: (a) The employer did not develop and implement a written confined space program for the Plank and Tahoe job site. The employer did not comply with the requirements of the American National Standards Institute (ANSI/ASSE) Z117.1-2003: Safety Requirements for Confined Space, paragraph 3.6 and 3.6.1. (b) A confined space permit was not completed prior to a worker entering a Permit Required Confined Space (PRCS) manhole approximately 13 feet deep, as required by ANSI/ASSE Z117.1- 2003, paragraphs 5.1 through 5.5. (c) Atmospheric testing was not done prior to a worker entering into a PRCS manhole approximately 13 feet deep, as required by ANSI/ASSE Z117.1-2003, paragraphs 6.1 through 6.3.2.2. (d) Emergency procedures were not in place for PRCS entry including means of providing timely rescue for employees entering into sewer manholes as required by ANSI/ASSE Z117.1-2003, paragraphs 7.1.3.3 and 7.4.1.1(3). Among other methods, feasible methods of abatement would be to develop and implement a written confined space program complying with the American National Standards Institute, ANSI/ASSE Z117.1-2003; Safety Requirements for Confined Space or the OSHA General Industry Standards 1910.146. Abatement Certification and Abatement Documentation required.
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
1926.1053 B01
- Issued
- Abate by
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309834349.