PARACHUTE, CO —
OSHA Inspection: PETROLEUM DEVELOPMENT CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PETROLEUM DEVELOPMENT CORP in GARDEN GULCH COMPRESSOR STATION, PARACHUTE, CO 81635 (NAICS 211111). OSHA activity number 310464565.
Where did this inspection happen?
- Establishment
- PETROLEUM DEVELOPMENT CORP
- Site address
- GARDEN GULCH COMPRESSOR STATION
- City
- PARACHUTE
- State
- CO
- ZIP
- 81635
- Mailing
- 120 GENESIS BLVD., BRIDGEPORT, WV 26330
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- SIC code (legacy)
- 1311
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1750.00 · Current $1225.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns and/or asphyxiation due to inadvertent release of pressurized natural gas: a) Petroleum Development Corp., Garden Gulch compressor station, Parachute, Colorado: On and prior to 2/13/2007, employee(s) installing a "water knockout" receiver system were exposed to the hazard of burns and/or asphyxiation due to inadvertent release of pressurized natural gas. The control valves used to isolate a 2200 foot long 8" gas line prior to being worked on were capable of being opened prematurely. Premature opening of these isolation valves would allow flammable gas into the area where heat and spark producing equipment was being used. Among other methods, one feasible and acceptable abatement method to correct this hazard is to develop and implement a written hazardous energy control program in accordance with the American National Standards Institute (ANSI)- American Society of Safety Engineers (ASSE) Z244.1-2003 publication. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.141 C01 I
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 211111)
MORGANTOWN, WV—2024-08-21 00:00:00
ANDERSON EXCAVATING, LLC
PINEVILLE, NC—2024-03-05 00:00:00
156148 - WESTERN INTERNATIONAL, INC.
SOUTH BEND, IN—2021-10-06 00:00:00
112385 - MERCURIA
GEARY, OK—2021-03-23 00:00:00
DEVON ENERGY CORPORATION
BAKERSFIELD, CA—2021-02-12 00:00:00
CHEVRON U.S.A. INC.
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310464565.