DENVER, CO —
OSHA Inspection: JET P.I. LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JET P.I. LLC in 1935 WEST 12TH AVE, DENVER, CO 80204 (NAICS 541890). OSHA activity number 310469481.
Where did this inspection happen?
- Establishment
- JET P.I. LLC
- Site address
- 1935 WEST 12TH AVE
- City
- DENVER
- State
- CO
- ZIP
- 80204
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541890
- SIC code (legacy)
- 7319
- Employees
- 2
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $375.00 · Current $375.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to a high pressure hydrogen peroxide hazard: (a)Jet P.I. LLC, at 1935 West 12th Avenue, Denver, CO: On 9/18/07, Jet P.I. LLC did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that one employee was exposed to a high pressure hydrogen peroxide hazard. The employer used a stainless steel cylinder to contain 89hydrogen peroxide. Compressed nitrogen was used to pressurize the hydrogen peroxide in excess of five hundred psi. The employer did not ensure that the cylinder used to contain the high pressure hydrogen peroxide was inspected and approved for containing the hydrogen peroxide at high pressure. This condition exposed one employee to a high pressure hydrogen peroxide hazard. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter"). Abatement Note: Among other methods, feasible abatement methods include: 1.Hydrotesting and certification of the stainless steel cylinders for containment of high pressure and concentration (approximately eighty nine percent) hydrogen peroxide by a qualified engineer. 2.The inspection process is outlined in ASME Boiler and Pressure Vessel Code, Section VIII "Rules for Construction of Pressure Vessels".
Recent events (2)
- — I (S) $375.00
- — Z (S) $375.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1000.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to a fire hazard: (a)Jet P.I. LLC, at 1935 West 12th Avenue, Denver, CO: On 9/12/07, Jet P.I. LLC did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to a fire hazard. One employee performed distillations of hydrogen peroxide at approximately 70 degrees Celsius using a vacuum pump. The distillation was performed to concentrate the hydrogen peroxide from approximately fifty percent to eighty nine percent. The heating element for the distillation was controlled by a thermostat that was not interlocked with the vacuum pump. Loss of vacuum would not result in an automatic shut down of the heating element. The room in which the distillation took place did not have an automatic sprinkler system. The vacuum system did not utilize a cold trap to prevent potential hydrogen peroxide vapor from entering the vacuum piping or pump. The overpressure relief did not have offset vents, which would prevent hydrogen peroxide liquid from escaping the flask. The glassware was cleaned with acetone and distilled water, which are reactive with hydrogen peroxide. Eighty nine percent concentration hydrogen peroxide at elevated temperature may cause an explosion or fire if allowed to come into contact with incompatible materials. The employer did not ensure that the distillation apparatus and the room in which the distillation took place were designed and constructed to prevent an explosion or fire involving hydrogen peroxide. This condition exposed employees to a fire hazard. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter"). Abatement Note: Among other methods, feasible abatement methods include: 1.Obtain 89hydrogen peroxide from a commercial source. 2.Ensure compliance with National Fire Protection Association Chapter 430 "Storage of Liquid and Solid Oxidizers" for Class II and III oxidizing liquids.g
Recent events (2)
- — I (S) $1000.00
- — Z (S) $1500.00
1910.120 Q06 III
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $925.00 Reduced
Recent events (2)
- — I (S) $925.00
- — Z (S) $1500.00
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $400.00 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $525.00
1910.133 A01
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.138 A
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $400.00 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $525.00
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $400.00 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $525.00
1910.1200 G08
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
More inspections in this industry (NAICS 541890)
KATY, TX—2026-06-23
FTS T-SHIRTS & SIGNS
TROY, MI—2026-02-03
CHUCK MOORE'S COMMERCIAL SIGN SERVICE, LLC
MACEDON, NY—2026-01-23
WOLFF/SMG
PORTLAND, OR—2025-12-23
317742805 - PETER L MCKEARNAN
HOUSTON, TX—2025-11-25
BUFFALO SPECIALTIES, INC.
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310469481.