Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DARREN STOLTE DBA RHINO DISPLAYS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DARREN STOLTE DBA RHINO DISPLAYS in 8000 BROADWAY STREET, QUINCY, IL 62301 (NAICS 713990). OSHA activity number 310796859.

Watch Darren Stolte DBA Rhino Displays — free Get an email when a new federal OSHA severe-injury report for Darren Stolte DBA Rhino Displays is published. One employer, no account, unsubscribe in one click.
Site address
8000 BROADWAY STREET
City
QUINCY
State
IL
ZIP
62301
Mailing
1203 350TH AVENUE, PAYSON, IL 62360
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713990
SIC code (legacy)
7999
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $1000.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being struck by a pyrotechnic aerial shell:
On or about 05/28/07, employees working for Rhino Displays at the Quincy
Raceway were
exposed to the hazard of being struck by a pyrotechnic aerial shell when
they stapled quick
match fuse to the wooden mortar racks in violation of the Nation Fire
Protection Association
NFPA 1123, Code for Fireworks Display, 2006 Edition, Section 4.6.4  which
states "Staple
guns shall not be permitted to be used to secure quick match that is
connected to aerial shells,
mines, or comets."
Among other methods, one feasible and acceptable abatement method to
correct this hazard is
to secure the quick match with a rubber band wrapped around the mortar,
secure
the quick
match with duct tape, secure the quick match using string to tie it down,
or by a combination
of these methods.ion
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310796859.