Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PAR ELECTRICAL CONTRACTORS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PAR ELECTRICAL CONTRACTORS, INC. in 6765 TRADE CENTER AVE., BILLINGS, MT 59101 (NAICS 238210). OSHA activity number 311214720.

Watch PAR Electrical Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for PAR Electrical Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6765 TRADE CENTER AVE.
City
BILLINGS
State
MT
ZIP
59101
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
4500
Ownership type
A

6 citations on file for this inspection.

1910.132 D01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Abate by
Recent events (2)
  • — F (O)
  • — Z (O)

1910.145 C03

Other-than-serious Gravity 03 1 instance 6 exposed
Issued
Abate by
Recent events (2)
  • — F (O)
  • — Z (O)

1926.553 A04

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $21000.00 · Current $21000.00
Recent events (2)
  • — F (S) $21000.00
  • — Z (S) $21000.00

5(a)(1)

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that
employees of
Cummins Rocky Mountain LLC and PAR Electrical Contractors, Inc were
exposed to the hazard
of being struck by flying parts/pieces as a base mounted drum hoist was
being tested by applying
tension to a polyester rope tied to a crane scale to measure tension:
(a) Establishment Site: On or about 04/21/08 an employee was fatally
struck by a crane scale
during tension testing operations when the 5/8" polyester rope failed as
he walked under the line.
Feasible and acceptable methods to correct this hazard are:
(1) Use a rope with a Safe Working Load/Maximum Working Load Rating with
the size, grade,
and construction able to withstand the load imposed.
(2) Have used the manufacturers recommended splice.
(3) Have the engineer who designed this Base Mounted Drum Hoist share the
design
information/load rating specifications with PAR Electrical Contractors,
Inc
so they can make a
Load Rating Tag and attach it to the Base Mounted Drum Hoist and train
their employees of its
limitations.
(4) Have the engineer who designed this Base Mounted Drum Hoist design a
brake system so
that the employees of PAR Electrical Contractors, Inc don't have to change
the hydraulic bypass
settings on the Base Mounted Drum Hoist to keep the Drum secured.
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

1910.132 D01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

1910.145 C03

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

View PAR ELECTRICAL CONTRACTORS, INC.'s full OSHA safety record →