PRIMM, NV —
OSHA Inspection: AMERICAN GLASS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMERICAN GLASS in 31900 LAS VEGAS BLVD., SOUTH, PRIMM, NV 89019 (NAICS 561720). OSHA activity number 311643860.
Where did this inspection happen?
- Establishment
- AMERICAN GLASS
- Site address
- 31900 LAS VEGAS BLVD., SOUTH
- City
- PRIMM
- State
- NV
- ZIP
- 89019
- Mailing
- 2350 SOUTH JONES BLVD., SUITE 6D, LAS VEGAS, NV 89146
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- SIC code (legacy)
- 7349
- Employees
- 4
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
618037501
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to furnish employment and a place of employment which was free from recognized hazards for employees cleaning windows at the Buffalo Bill's Resort & Casino, as follows: a.Suspended work was allowed to be performed when it had not been determined that the building had provided, identified and certified anchorages for independent safety lines and primary support anchorage for rope descent systems. The employer had utilized four metal pipes as anchorage but the pipes had not been approved/certified by a registered professional engineer. Ropes for the Rope Descent and Personal Fall Arrest Systems were tied around the unsecured pipes that were lying in front of the doorways of the hotel rooms. The ropes were then carried into an adjacent hotel room and tied around the toilet. These anchorages were used without certifying that the doorways and toilets could hold the employees as they rappelled down the face of the hotel to wash the windows. Reference: ANSI/IWCA I-14.1-2001, Window Cleaning Safety, Section 3.9, Anchorages, "Building owners and window cleaning contractors shall not allow suspended work to be performed unless it has been determined that the building has provided, identified and certified anchorages complying with section 9 or 10." AND, Section 5.7.17(a), Suspension Devices for Rope Descent Systems, "A rope descent system may be suspended from equipment that is transported from building to building, providing that the design of the support apparatus and the part of the structure where it is placed has been approved by a registered professional engineer for all loads that will be imposed in accordance with section 9 and 17 of this standard." b.Independent anchorages for personal fall arrest systems were not used by the employees while washing windows on the face of the building. In four hotel rooms the ropes for the Rope Descent and Personal Fall Arrest Systems were tied around an unsecured metal pipe lying in front of the doorway to each of the hotel rooms and then tied around a toilet in an adjacent hotel room. Reference: ANSI/IWCA I-14.1 - 2001, Window Cleaning Safety, Section 5.7.6, Rope Descent Systems (RDS), "Operators of rope descent systems shall utilize and be safely secured to an independent fall arrest system complying with section 3.8 and 5.7.4 and section 9.2" c.A rope log recording the use of the lifelines was not provided when requested. Reference: ANSI/IWCA I-14.1 - 2001, Window Cleaning Safety, Section 9.2.2(e), Personal Fall Arrest System, "Ropes shall be inspected according toSection 5.7.16(d) and a means shall be provided by the employer to identify and log the use of lifelines." The employees were exposed to a fall of up to 14 stories (15 floors) to the concrete slabs below. One feasible means of abatement would be to ensure that all aspects of the ANSI/IWCA I-14.1-2001, Window Cleaning Safety, standard are followed.
Recent events (2)
- — I (S) $1400.00
- — Z (S) $2000.00
618037501
- Issued
- Abate by
- Penalty
- Initial $625.00 · Current $438.00 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that the place of employment was free from recognized hazards for employees cleaning windows at Buffalo Bill's Resort & Casino, as follows: a.Employee training did not include job conditions other than working from the roof of buildings. Employees were and had been, rappelling from the windows of the hotel rooms from 5/5 to 5/9/08 and were not properly anchored. Employees were descending from the top of the 15 story building while washing windows using a Rope Descent System (RDS). Reference: ANSI/IWCA I-14.1-2001; "Window Cleaning Safety", Section 5.7.2; Rope Descent Systems (RDS). "Employees shall be trained in the use and care of rope descent systems before they are permitted to use such equipment. Training shall include but not limited to understanding the manufacturer's instructions, inspection of components, accepted rigging practices, identifying anchorages, descending, fall arrest requirements, rescue consideration and a full understanding of safe working conditions considering as a minimum, correct rigging, rope use, inspection and care the effects of wind on suspended operations." AND Section 3.4.1, Training, Instruction and Supervision, "Employers and employees shall be proficient in safety working procedures and proper use of equipment." b.The employer did not provide manufacturer's instructions for all of the employee equipment when requested. Reference: ANSI/IWCA I-14.1-2001; "Window Cleaning Safety", Section 3.4.3, Training, Instruction and Supervision, "Manufacturer's instructions shall be provided to the users for all equipment utilized in the performance of their tasks." AND Section 14.1.3, Rope Descent Systems (DRS) Specifications, "Individual components of a RDS without specific instructions for their use shall be prohibited." One feasible means of abatement is to follow the requirements of ANSI/IWCA I-14.1- 2001; "Window Cleaning Safety".
Recent events (2)
- — I (S) $437.50
- — Z (S) $625.00
618037501
- Issued
- Abate by
- Penalty
- Initial $625.00 · Current $438.00 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): Duties of employers. The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to his employees: The employer failed to furnish employment and a place of employment which was free from recognized hazards for employees cleaning windows at the Buffalo Bill's Resort & Casino, as follows: a.The Plan of Service, also known as the work plan, was not onsite during the walkaround portion of the inspection and had not been provided to the Buffalo Bill's Resort & Casino. Employees had been cleaning windows from the 15th floor for approximately four and one half days. Reference: ANSI/IWCA I-14.1-2001, Window Clean Safety, Section 1.7, Plan of Service, "A written plan developed by the window cleaning contractor or qualified person shall be provided that will inform the building owner or their operating agents when windows to be cleaned are located in areas where workers may utilize suspended equipment or; where workers are exposed to falls and other known hazards or; where the public may be exposed to overhead equipment operations." Abated During Inspection 5/19/08. b.The Emergency Recovery Plan, part of the Plan of Service and the Written Safety and Health Program, did not include emergency recovery from windows. Employees were and had been rappelling from the windows of the hotel rooms to wash the outside of the windows from 5/5-5/9/08. The plan had rooftop recovery only. Reference: ANSI/IWCA I-14.1-2001, Window Clean Safety, Section 1.8, Emergency Recovery, "In the event of power failure, equipment failure or disability of any nature, means and procedures shall be established and provided for the safe emergency recovery of persons working from suspended equipment or other types of installations." c.The work plan did not include, that prior to making a descent, the requirement to inspect the building exterior, take appropriate measures as need to prevent impairment of the structural integrity of the RDS or associated fall protection rigging, and secure padding when used. Reference: ANSI/IWCA I-14.1-2001, Window Cleaning Safety, Section 5.7.5, Rope Descent Systems (RDS), "Prior to making a descent, the building exterior shall be visually inspected and where necessary, shall be taken to ensure that building features, such as sharp edges of parapets, window frames, open projected windows and cornices or overhangs cannot impair the structural integrity of the RDS or associated fall protection rigging. When used, padding shall be secured to prevent its dislodging from the surface to be protected. Thesemeasures shall be incorporated into the work plan in accordance with section 1.7 of this standard." The employees were exposed to a fall of up to 14 stories (15 floors) to the concrete slabs below. One feasible means of abatement would be to ensure that all aspects of the ANSI/IWCA I-14.1-2001, Window Cleaning Safety, standard are followed.
Recent events (2)
- — I (S) $437.50
- — Z (S) $625.00
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $625.00 · Current $438.00 Reduced
Recent events (2)
- — I (S) $437.50
- — Z (S) $625.00
More inspections at AMERICAN GLASS
SPRINGFIELD, MO—2019-10-30 00:00:00
AMERICAN GLASS
LAS VEGAS, NV—2009-02-06 00:00:00
AMERICAN GLASS
LAS VEGAS, NV—2008-11-20 00:00:00
AMERICAN GLASS
LAS VEGAS, NV—2008-04-04 00:00:00
AMERICAN GLASS
LAS VEGAS, NV—2008-01-03 00:00:00
AMERICAN GLASS
View AMERICAN GLASS's full OSHA safety record →
More inspections in this industry (NAICS 561720)
PALM BAY, FL—2026-07-10
ASCEND BUILDING SERVICES, LLC
NOLENSVILLE, TN—2026-07-08
BUSY BS RESIDENTIAL CLEANING COMPANY
TACOMA, WA—2026-07-07
WA317991946 - COASTAL BUSINESS SERVICES GROUP INC
POULSBO, WA—2026-07-07
WA317991849 - SIMPLY HOUSE CLEANING LLC
DIXON, CA—2026-07-07
SANITATION PROCESS CONTROL, LLC
More inspections in NV
RENO, NV—2026-07-16
DC MASONRY
CARSON CITY, NV—2026-07-16
LT BUILDERS
ZEPHYR COVE, NV—2026-07-16
DOLLAR TREE STORES, INC.
SPARKS, NV—2026-07-16
SYUFY ENTERPRISES
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311643860.