Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHARTER BAKING CORP. DBA THE BAKER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHARTER BAKING CORP. DBA THE BAKER in 60 BRIDGE ST./P.O. BOX 528, MILFORD, NJ 08848 (NAICS 311812). OSHA activity number 311916142.

Watch Charter Baking Corp. DBA THE Baker — free Get an email when a new federal OSHA severe-injury report for Charter Baking Corp. DBA THE Baker is published. One employer, no account, unsubscribe in one click.
Site address
60 BRIDGE ST./P.O. BOX 528
City
MILFORD
State
NJ
ZIP
08848
Mailing
P.O. BOX 898, NORTH GROSVENORDALE, CT 06255
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
SIC code (legacy)
2051
Employees
42
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2925.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of falling into the elevator shaft and/or being
struck by the elevator
car:
a/  The Baker/Milford NJ Site - Production Area:  The 'Freight Elevator'
used to
ascend/descend from the basement to the second level of the facility was
not in proper
operating condition, in that, the gates to the elevator on each level were
not designed to
prevent the gates from being opened when the car was not on that level.
Observed on
or about 9/23/08.
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to:
1/  Provide interlocks (limit switches) on each gate of freight elevator.
a/  The interlock device shall hold the gate in the locked position by
means of gravity
or by a restrained compression spring, (or by both) and/or by means of a
positive
linkage.
b/  The interlock device shall lock the door in the closed position before
the elevator
can be operated.  When the interlock is released, the elevator is to be
rendered
inoperable.
2/  And/or other approved means.
REFERENCE:
American National Standard Institute (ANSI) American Society of Mechanical
Engineers
A17.3, 1986 - 'Safety Code for Existing Elevators and Escalators.
BOCA - Basic Building Code - Article 26
Recent events (2)
  • — I (S) $2925.00
  • — Z (S) $4500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311916142.