DAVENPORT, OK —
OSHA Inspection: DRUMRIGHT OILWELL SERVICE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DRUMRIGHT OILWELL SERVICE, LLC in DAVENPORT PRUE SAND UNIT WELL #133 SEC 3-14N-5E, DAVENPORT, OK 74023 (NAICS 213112). OSHA activity number 312383425.
Where did this inspection happen?
- Establishment
- DRUMRIGHT OILWELL SERVICE, LLC
- Site address
- DAVENPORT PRUE SAND UNIT WELL #133 SEC 3-14N-5E
- City
- DAVENPORT
- State
- OK
- ZIP
- 74023
- Mailing
- 501 W TRUCK BYPASS, DRUMRIGHT, OK 74030
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $2500.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: Davenport Prue Sand Unit Well #133; on or about April 16, 2009, employees were engaged in the operation of a well service rig to replace a broken (parted) sucker rod, they had pulled the sucker rod to the break storing it in the rig mast rod rack; the rig stabilizing guylines were not attached to anchors leaving the rig stabilized only by the carrier supports and guylines attached to the carrier front. This exposed all the employees to the hazards of a rig overturning as being struck by rig and well components, and falling from mast elevations upwards of 80 feet. The American Petroleum Institute (API) Recommended Practice (RP) 54, Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, 6.3.2 requires that the rig be rigged up in a safe manner before starting well operations with the rig, and 9.2.10 requires that the rig guylines be properly tensioned prior to imposing a load on the derrick or mast. Among other methods, one feasible and acceptable abatement method to correct this hazard is to assure that the rig is safely rigged up prior to the imposition of any operational load on the rig mast and that the guylines are properly tensioned to certified anchors.d
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $875.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: Davenport Prue Sand Unit Well #133; on or about April 16, 2009, employees were operating an oil/gas service rig to replace a broken (parted) sucker rod in the well, the derrick hand was working in the 80 foot high rod basket manually racking the sucker rods; the derrick hand was not provided a secondary means of emergency egress from the mast. This prevented the derrick hand from making timely emergency egress from the mast during rig emergencies; potential emergency hazards include: fire, explosion, flying objects and rig collapse. The American Petroleum Institute (API) Recommended Practice (RP) for Occupational Safety for Oil and Gas Well Drilling Servicing Operations, RP 54, 6.10.1 requires that an auxiliary means escape be installed prior to the derrick hand working on the mast. Among other methods, one feasible and acceptable abatement method to correct this hazard is to assure that the escape system is installed in accordance with the manufacturer's instructions prior to the placement of the derrick hand in the mast.
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $700.00 · Current $700.00
1910.184 E03 I
- Issued
- Abate by
1910.184 E01
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $525.00
More inspections in this industry (NAICS 213112)
COLLBRAN, CO—2026-07-14
LARAMIE ENERGY
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312383425.