Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DNV GLOBAL ENERGY CONCEPTS INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of DNV GLOBAL ENERGY CONCEPTS INC in SITE 109, NE OF TX GULF WIND PROJECT, SARITA, TX 78385 (NAICS 238210). OSHA activity number 312733686.

Watch DNV Global Energy Concepts INC — free Get an email when a new federal OSHA severe-injury report for DNV Global Energy Concepts INC is published. One employer, no account, unsubscribe in one click.
Site address
SITE 109, NE OF TX GULF WIND PROJECT
City
SARITA
State
TX
ZIP
78385
Mailing
1809 7TH AVENUE SUITE 900, SEATTLE, WA 98101
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.502 D15

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2500.00 · Current $5000.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer does not
furnish employment and a place of employment which are free from
recognized hazards that are
causing or likely to cause death or serious physical harm to employees in
that employees are
exposed to fall hazards:
At site S109, NE of Texas Gulf Wind Project: On or about 11/09/08,
employees
are exposed to fall hazards.  This exposure occurs while ascending and
working
upon the following unsecured steel tower sections vertically positioned
upon the
ground:
a.Metrology tower segment S09,
b.Metrology tower segment S06-1.
Pursuant to 29 CFR 1903.19, the employer must submit documentation showing
it is in compliance with the standard, including describing the steps it
is taking
to ensure that vertically positioned, ground supported tower segments are
properly
anchored prior to use by employees.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to properly secure the tower to the ground using an approved
system of anchoring devices.
Recent events (2)
  • — F (O) $5000.00
  • — Z (S) $2500.00

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2500.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer does not
furnish employment and a place of employment which are free from
recognized hazards that are
causing or likely to cause death or serious physical harm to employees in
that employees are
exposed to struck-by hazards:
At site S109, Texas Gulf Wind Project: On or about 11/09/08, employees are
exposed to being struck by falling tower section while working near
unsecured
steel tower sections. The following sections are vertically positioned
upon the
ground with potential for being accidentally toppled by wind gusts,
employee
climbing activities, or unstable tower footings:
a.Metrology tower segment S09,
b.Metrology tower segment S06-1.
Pursuant to 29 CFR 1903.19, the employer must submit documentation showing
it is in compliance with the standard, including describing the steps it
is taking
to ensure that vertically positioned, ground supported tower segments are
properly
anchored prior to use by employees.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to properly secure the tower to the ground using an approved
system of anchoring devices.g
Recent events (2)
  • — F (S)
  • — Z (S) $2500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312733686.