SLEEPY HOLLOW, NY —
OSHA Inspection: PETER GROTTO PLUMBING & HEATING INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PETER GROTTO PLUMBING & HEATING INC. in 1 NEW BROADWAY, SLEEPY HOLLOW, NY 10591 (NAICS 238220). OSHA activity number 312997349.
Where did this inspection happen?
- Establishment
- PETER GROTTO PLUMBING & HEATING INC.
- Site address
- 1 NEW BROADWAY
- City
- SLEEPY HOLLOW
- State
- NY
- ZIP
- 10591
- Mailing
- 895 NEPPERHAN AVENUE, YONKERS, NY 10701
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $750.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being caught by rotating parts: Location: Garage Area, 1 New Broadway, Sleepy Hollow NY 10591 On or about 6/3/09 a) A Ridgid 300 T2 pipe threading machine SN ED-77122-E02 was operated without a momentary contact device such as a foot pedal. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THE HAZARD IS: to establish and enforce adequate safe operating procedures. Procedures such as those stipulated in American National Standard for Portable Pipe Threading Machines (ANSI B208.1). Elements essential to acceptable safe operating procedures include at a minimum: installation of a momentary contact device (deadman foot switch) to control power input to the machine. This device would automatically stop the machine and the rotating pipe if the operator's foot was removed from the foot switch for any reason.
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $900.00 · Current $450.00 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $900.00
More inspections at PETER GROTTO PLUMBING & HEATING INC.
YONKERS, NY—2016-11-03 00:00:00
PETER GROTTO PLUMBING & HEATING INC.
SLEEPY HOLLOW, NY—2009-03-24 00:00:00
PETER GROTTO PLUMBING & HEATING INC.
View PETER GROTTO PLUMBING & HEATING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source