Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EQUISTAR CHEMICAL, LP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EQUISTAR CHEMICAL, LP in 340 MEADOW RD., EDISON, NJ 08817 (NAICS 331311). OSHA activity number 313979874.

Watch Equistar Chemical, LP — free Get an email when a new federal OSHA severe-injury report for Equistar Chemical, LP is published. One employer, no account, unsubscribe in one click.
Site address
340 MEADOW RD.
City
EDISON
State
NJ
ZIP
08817
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331311
SIC code (legacy)
2819
Employees
65
Ownership type
A
Industry flags
Manufacturing safety.

6 citations on file for this inspection.

1910.119 E03 V

Deleted Serious Gravity 10 1 instance 35 exposed
Issued
Abate by
Penalty
Initial $4500.00
29 CFR 1910.119(e)(3)(v):  The process hazard analysis did not address
facility siting:
Equistar Chemicals Edison NJ Site - Facilty Wide
a) The 2006 PHA did not address facility siting for the entire facility
with respect to the
Catalyst Production process and the effects of a catastrophic event on all
neighboring
buildings, vessels and structures.
Condition noted on or about 5/28/2010 and 9/9/2010.
Recent events (3)
  • — R (S)
  • — J (S)
  • — Z (S) $4500.00

1910.119 J02

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $3600.00 Reduced
29 CFR 1910.119(j)(2):  The employer did not establish and implement
written procedures to
maintain the on-going mechanical integrity of process equipment:
operating conditions existed before employees began the changeout
procedure.
Condition noted on or about 5/28/2010.
Recent events (3)
  • — R (S) $3600.00
  • — J (S) $3600.00
  • — Z (S) $4500.00

1910.119 J05

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $3600.00 Reduced
29 CFR 1910.119(j)(5):  The employer did not correct deficiencies in
equipment that were
outside acceptable limits (as defined by process information in 29 CFR
1910.119(d) before
further use or in a safe and timely manner:
Equistar Chemicals Edison NJ site - Building 6
a) C6-202: The pressure gauge PI-213 was not operational.
Condition noted on or about 4/7/2010.
Recent events (3)
  • — R (S) $3600.00
  • — J (S) $3600.00
  • — Z (S) $4500.00

1910.119 L01

Serious Gravity 10 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $3600.00 Reduced
29 CFR 1910.119(l)(1):  The employer did not establish and implement
written procedures to
manage changes to process chemicals, technology, equipment, and
procedures; and, changes to
facilities that affect a covered process:
Equistar Chemicals Edison NJ site - Building 6:
a) A PMA (MOC) was not written for the change of PPE requirements in the
"C202
Change Out" procedure. There was no evaluation performed to determine the
possible
hazards of changing from cotton uniforms to Pyrolon CRFR uniforms and from
rubber
gloves to nitrile gloves.
Condition noted on or about 4/12/2010.
Recent events (3)
  • — R (S) $3600.00
  • — J (S) $3600.00
  • — Z (S) $4500.00

1910.119 M06

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $3600.00 Reduced
29 CFR 1910.119(m)(6):  The incident investigation report was not reviewed
with all affected
personnel, including contract employees whose job tasks are relevant to
the incident findings:
Equistar Chemicals Edison NJ Site - Building 6
a) On 4/7/2010, maintenance employees performing a routine mole sieve
change out the
the C-202 column were exposed to a flash fire. An incident investigation
was performed
and completed on 5/10/2010 but was not reveiwed with all affected
employees.
Condition noted on or about 9/21/2010.
Recent events (3)
  • — R (S) $3600.00
  • — J (S) $3600.00
  • — Z (S) $4500.00

1910.303 G01 II

Serious Gravity 02 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $1200.00 Reduced
29 CFR 1910.303(g)(1)(ii):  Working space about electric equipment rated
600 volts, nominal,
or less was used for storage:
Equistar Chemicals Edison NJ Site -
a) Maintenance Shop/ Welding Area: Electrical panel boxes/ junction boxes
rated 480V/3
phase and 220V single phase that controlled a welding machine, the exhaust
fan and a
lathe in the building were not maintained free of storage. The areas were
blocked with
items including but not limited to machinery, power cords and various
other tools.
Condition noted on or about 8/26/2010
Recent events (3)
  • — R (S) $1200.00
  • — J (S) $1200.00
  • — Z (S) $1500.00

View EQUISTAR CHEMICAL, LP's full OSHA safety record →