HUNTSVILLE, AL —
OSHA Inspection: PINPOINT LOCATING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PINPOINT LOCATING, INC. in 4493 REDSTONE ARSENAL, HUNTSVILLE, AL 35806 (NAICS 237110). OSHA activity number 314104068.
Where did this inspection happen?
- Establishment
- PINPOINT LOCATING, INC.
- Site address
- 4493 REDSTONE ARSENAL
- City
- HUNTSVILLE
- State
- AL
- ZIP
- 35806
- Mailing
- 196 COBBLY NOB LANE, ONEONTA, AL 35121
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- SIC code (legacy)
- 1781
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $750.00 · Current $563.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of getting caught in equipment: (a) On or about 02/08/2010 - 4493 Redstone Arsenal, Huntsville, AL, employees were working in the area in close proximity to a Ditch Witch (Model JT3020) that was used for the directional drilling operation and a safety buffer zone of at least 10 feet was not established. Warning signs were not placed in the area. Among other methods, one feasible and acceptable method to correct this hazard would be to establish a buffer zone around the equipment in accordance with the Operator's Manual for the Ditch Witch in the Inspection Site Section, Prepare 77 and provide warning signs in accordance with "Guidelines for Use of Mini-Horizontal Directional Drilling for Placement of High Density Polyethylene Pipe", TR-46, 2009, published for the Plastics Pipe Institute.
Recent events (2)
- — F (S) $563.00
- — Z (S) $750.00
1926.20 B02
- Issued
- Abate by
Recent events (2)
- — F (S)
- — Z (S)
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in AL
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
LOXLEY, AL—2026-07-16
CARLOS CHE
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
BIRMINGHAM, AL—2026-07-14
SCHOLAR CRAFT PRODUCTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314104068.