PITTSBURGH, PA —
OSHA Inspection: NVR, INC. DBA RYAN HOMES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NVR, INC. DBA RYAN HOMES in 617 GLEN GARRY COURT, PITTSBURGH, PA 15239 (NAICS 236115). OSHA activity number 314113176.
Where did this inspection happen?
- Establishment
- NVR, INC. DBA RYAN HOMES
- Site address
- 617 GLEN GARRY COURT
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15239
- Mailing
- 300 BILMAR DRIVE, STE. 150, PITTSBURGH, PA 15205
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- SIC code (legacy)
- 1521
- Employees
- 2
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4500.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire, explosion, burn, asphyxiation, carbon monoxide poisoning and/or electrical shock hazards: (a) 617 Glen Garry Court, Pittsburgh, PA 15239: On or about February 26, 2011, the employer used a DESA propane construction heater and the following safety precautions in the owner's manual were not adhered to; safety precaution 21, do not leave heater unattended, safety precaution 4, provide adequate ventilation, precaution 13, use only the hose and factory preset regulator provided and safety precaution 8, do not use heater in basement or below ground level. On February 28, 2011, a massive explosion occurred when an employee tried to ignite this heater, resulting in first, second and third degree burns. Among others, one feasible and acceptable method to abate this hazard is to follow the owner's manual provided with the heater and comply with the National Fuel Gas Code (NFPA 54), specifically section 9.3, Air for Combustion and Ventilation when using the DESA Propane Construction Heater.
Recent events (2)
- — F (S) $4500.00
- — Z (S) $4900.00
More inspections at NVR, INC. DBA RYAN HOMES
SAINT AUGUSTINE, FL—2025-02-11
NVR, INC. DBA RYAN HOMES,
SAINT AUGUSTINE, FL—2024-09-23 00:00:00
NVR, INC. DBA RYAN HOMES,
BLUE ASH, OH—2023-04-03 00:00:00
NVR, INC. DBA RYAN HOMES
DEER PARK, OH—2023-01-11 00:00:00
NVR, INC. DBA RYAN HOMES
WESLEY CHAPEL, FL—2022-09-20 00:00:00
NVR, INC. DBA RYAN HOMES
View NVR, INC. DBA RYAN HOMES's full OSHA safety record →
More inspections in this industry (NAICS 236115)
REDDING, CA—2026-07-10
R&A RESOURCES, INC.
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
SAN JOSE, CA—2026-07-09
WALT OXLEY ENTERPRISES, INC.
BATAVIA, OH—2026-07-09
FISCHER SINGLE FAMILY HOMES IV, LLC
SARATOGA SPRINGS, UT—2026-07-09
JESSI CONSTRUCTION & PAINTING LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314113176.