URBANA, IL —
OSHA Inspection: GUARDIAN WEST, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GUARDIAN WEST, LLC in 601 GUARDIAN DRIVE, URBANA, IL 61802 (NAICS 336370). OSHA activity number 314847419.
Where did this inspection happen?
- Establishment
- GUARDIAN WEST, LLC
- Site address
- 601 GUARDIAN DRIVE
- City
- URBANA
- State
- IL
- ZIP
- 61802
- Mailing
- P.O. BOX 877, URBANA, IL 61803
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- SIC code (legacy)
- 3465
- Employees
- 387
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $4410.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to: On October 4, 2010, employees performing work activities in and around the Back Coating Oven Area were exposed to severe burn hazards because the emergency shut off valve was not readily accessible to those employees charged with closing the valve in the event of an emergency. NFPA Standard 86 - 2011, Standard for Ovens and Furnaces: Section 6.2.3.1: "An emergency shutoff valve shall be provided that meets the following requirements: a) It shall be remotely located away from the furnace so that fire or explosion at a furnace does not prevent access to the valve; b) It shall be readily accessible; c) It shall have permanently affixed visual indication of the valve position; d) A removable handle shall be permitted provided all the requirements of this section are satisfied; and e) It shall be able to be operated from full open to full close and return without the use of tools." Among other methods, feasible and acceptable abatement methods to correct this hazard is to comply with the guidelines of NFPA Standard 86 - 2011, Standard for Ovens and Furnaces, including, but not limited to: a) Make the designated emergency shutoff valve readily accessible; or b) Install an additional valve that is readily accessible to be used as a means of an emergency shutoff valve. ***Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)***
Recent events (2)
- — F (S) $4410.00
- — Z (S) $6300.00
1910.107 B03
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $3000.00 Reduced
Recent events (2)
- — F (O) $3000.00
- — Z (S) $6300.00
More inspections in this industry (NAICS 336370)
BEAVER DAM, KY—2026-07-01
69265 - RITATSU MANUFACTURING INC
BELLEVILLE, MI—2026-06-30
DIE SERVICES INTERNATIONAL, LLC
IMLAY CITY, MI—2026-06-29
DIETECH TOOL & MANUFACTURING INC
IONIA, MI—2026-06-29
VENTRA IONIA MAIN
IMLAY CITY, MI—2026-06-29
DIETECH TOOL & MANUFACTURING INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314847419.