MOUNT AIRY, MD —
OSHA Inspection: PHASE INCORPORATED
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PHASE INCORPORATED in 1604 BACK ACRE CIRCLE, MOUNT AIRY, MD 21771 (NAICS 332322). OSHA activity number 315611160.
Where did this inspection happen?
- Establishment
- PHASE INCORPORATED
- Site address
- 1604 BACK ACRE CIRCLE
- City
- MOUNT AIRY
- State
- MD
- ZIP
- 21771
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- SIC code (legacy)
- 3444
- Employees
- 13
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $525.00 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $525.00 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.1200 H03 II
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $525.00 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
50104 A
- Issued
- Abate by
- Penalty
- Initial $875.00 · Current $525.00 Reduced
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:08/02/11 Location:Sanding/Grinding Room Equipment:Donaldson Torit ECB-3 Condition:Employees were exposed to fire and explosion hazards from the generation of combustible fines while grinding, sanding, and buffing a variety of aluminum metal parts. In the Environmental Control Booth the aluminum dust was collected with a dry type collection system located inside which recirculated the air back into the work area. Among other methods, one feasible and acceptable abatement method to correct this hazard is to relocate the dry type dust collection system outside the building in a safe location. Perform a process hazard analysis/assessment on sanding aluminum products and the dust collection systems. Obtain a certification verifying the design, installation, operation, and maintenance of aluminum explosive/combustible dust collection system meets all applicable standards including, but not limited to, NFPA 484 Standard for Combustible Metals, 2009 Edition. (b)Date of Violation:08/02/11 Location:Outside Rear of Building Equipment:Dustkop and Mistkop Cyclone Collector Model #20T31-D1-SP Condition:Employees were exposed to fire and explosion hazards from the generation of combustible aluminum dust while sanding aluminum sheet metal parts with the dry type Time Saver Machine connected to a cyclone collector located outside the building. Dust collector was not properly bonded and grounded, lacked proper deflagration venting, lacked an abort valve, was not emptied daily, and lacked proper filter maintenance for dust collector. Among other methods, one feasible and acceptable abatement method to correct this hazard is to verify the design, installation, operation and maintenance of the aluminum dust collection system meets all applicable standards including, but not limited to, NFPA 484 Standard for Combustible Metals, 2009 Edition and NFPA 69 Standard on Explosive Prevention Systems 2008 Edition. Abatement documentation (photogrpahs, receipts, copies of programs, training certification, etc.) is required for this item.
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
09123302 A01
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
More inspections at PHASE INCORPORATED
MOUNT AIRY, MD—2017-05-02 00:00:00
PHASE INCORPORATED
MOUNT AIRY, MD—2014-02-20 00:00:00
PHASE INCORPORATED
ROCKVILLE, MD—1997-12-15 00:00:00
PHASE INCORPORATED
View PHASE INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 332322)
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
NEW ROCHELLE, NY—2026-07-09
HEFTI HARBOR ELEC FAB & TOOLS
LAKEWOOD, WA—2026-07-08
WA317992020 - KRUEGER SHEET METAL CO
SOUTHAMPTON, MA—2026-07-07
LYMAN SHEET METAL CO., INC
More inspections in MD
ELKRIDGE, MD—2026-07-10
MILBY COMPANY
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
HANOVER, MD—2026-07-09
OLIVE GARDEN
CLINTON, MD—2026-07-09
MONRO INC.
ANNAPOLIS, MD—2026-07-08
THIEL CO.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 315611160.