MIDDLETON, ID —
OSHA Inspection: BENNETT CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BENNETT CONSTRUCTION, INC. in HWY 44 WEST & HARTLEY ROAD, MIDDLETON, ID 83644 (NAICS 237110). OSHA activity number 330017229.
Where did this inspection happen?
- Establishment
- BENNETT CONSTRUCTION, INC.
- Site address
- HWY 44 WEST & HARTLEY ROAD
- City
- MIDDLETON
- State
- ID
- ZIP
- 83644
- Mailing
- 9809 HAYDEN WAY, MIDDLETON, ID 83644
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $1050.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) South side of roadway at shoulder; On or about 3/10/11 and at times prior thereto, an employee setting PVC pipe in an excavation ranging from 5.6 to 6.6 feet in depth with nearly vertical walls was required to travel approximately 44 feet to utilize the backfill slope for egress in/out of the excavation. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (S) $1050
- — Z (S) $4200
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) South side of roadway at shoulder; On or about 3/10/11 and at times prior thereto, an employee setting PVC pipe in an excavation ranging from 5.6 to 6.6 feet in depth with nearly vertical walls and excavated material had been placed immediately adjacent to or was sloughing down to the edge of the excavation. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. a) South side of roadway at shoulder; On or about 3/10/11 and at times prior thereto, a competent person did not perform an inspection of an excavation ranging from 5.6 to 6.6 feet in depth with nearly vertical prior to an employee entering the excavation to set PVC pipe. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) South side of roadway at shoulder; On or about 3/10/11 and at times prior thereto, an employee was setting PVC pipe in an excavation ranging from 5.6 to 6.6 feet in depth with nearly vertical walls without a means of protection. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 D
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $450.00 Reduced
General-duty citation text
29 CFR 1926.651(d): Employees exposed to public vehicular traffic were not provided with a warning vest or other suitable garments marked with or made of reflectorized or high-visibility material: a) South side of roadway; On or about 3/10/11 and at times prior thereto, two employees working in/adjacent to an excavation along an active roadway were not provided with and/or wearing a high visibility garment. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (S) $450
- — Z (S) $1800
More inspections at BENNETT CONSTRUCTION, INC.
MANCHESTER, OK—2013-04-19 00:00:00
BENNETT CONSTRUCTION, INC.
WEST OCEAN CITY, MD—2012-08-08 00:00:00
BENNETT CONSTRUCTION INC
LYONS, NY—1985-09-10
BENNETT CONSTRUCTION INC.
MESA, AZ—1985-07-30
BENNETT CONSTRUCTION INC
TONAWANDA, NY—1985-05-01
BENNETT CONSTRUCTION INC
View BENNETT CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
BRIDGEPORT, CT—2026-07-10
WRR, INC.
MARYSVILLE, WA—2026-07-09
WA317992011 - BDZ DEVELOPERS INC
PEORIA, IL—2026-07-08
WALTERS WATERWORKS LLC DBA MR. ROOTER PLUMBING OF PEORIA
TAMPA, FL—2026-07-08
DALLAS 1 CONSTRUCTION AND DEVELOPMENT, INC.
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330017229.