Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PIPER ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PIPER ROOFING in 9555 S. WINCHESTER AVE., CHICAGO, IL 60643 (NAICS 238160). OSHA activity number 330630252.

Watch Piper Roofing — free Get an email when a new federal OSHA severe-injury report for Piper Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
PIPER ROOFING
Site address
9555 S. WINCHESTER AVE.
City
CHICAGO
State
IL
ZIP
60643
Mailing
2428 OAK, BLUE ISLAND, IL 60406
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    On or about May 31, 2011 - at the above addressed jobsite, employees performing roofing operations on a residential steep roof, approximately twenty one (21) feet above the ground, were not protected from falls, thereby exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330630252.