MEDFORD, WI —
OSHA Inspection: WAY & WAY PLUMBING & HEATING, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAY & WAY PLUMBING & HEATING, INC in 209 N. 8TH STREET, MEDFORD, WI 54451 (NAICS 238220). OSHA activity number 330772666.
Where did this inspection happen?
- Establishment
- WAY & WAY PLUMBING & HEATING, INC
- Site address
- 209 N. 8TH STREET
- City
- MEDFORD
- State
- WI
- ZIP
- 54451
- Mailing
- 426 S. 8TH STREET, MEDFORD, WI 54451
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $4200.00
General-duty citation text
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. a) Excavation site located at Taylor County Highway Department building, Medford, WI; The extension ladder used for egress was located approximately 33 feet away from where two employees were working.
Recent events (1)
- — Z (S) $4200
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Excavation site located at Taylor County Highway Department building, Medford, WI; A spoil pile on the southwest end of the trench was located on the edge of the trench sidewall.
Recent events (1)
- — Z (S) $0
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. a) Excavation site located at Taylor County Highway Department building, Medford, WI; Daily inspections of this trench were not conducted prior to Craig Way (owner) and his employee entering a trench, which was approximately 11 feet, 9 inches deep.
Recent events (1)
- — Z (S) $0
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $4200.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:a) Excavation site located at Taylor County Highway Department building, Medford, WI; Cave-in protection was not provided for two Way & Way Plumbing & Heating, Inc., employees working in a trench measuring approximately 11 feet, 9 inches in depth.
Recent events (1)
- — Z (S) $4200
More inspections in this industry (NAICS 238220)
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
RIO RANCHO, NM—2026-07-15
PROFESSIONAL STUCCO & SERVICE INC.
BROOKLYN, NY—2026-07-15
DILIGENT AC LLC
PARKVILLE, MD—2026-07-15
AMERICAN AUTOMATIC SPRINKLER COMPANY, INC.
SACRAMENTO, CA—2026-07-15
J.R. PIERCE PLUMBING CO., INC. OF SACRAMENTO
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330772666.