WAUWATOSA, WI —
OSHA Inspection: DEUTSCHER BUILDING RESTORATION LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of DEUTSCHER BUILDING RESTORATION LLC in 1337 N. 116TH ST., WAUWATOSA, WI 53226 (NAICS 238160). OSHA activity number 330924721.
Where did this inspection happen?
- Establishment
- DEUTSCHER BUILDING RESTORATION LLC
- Site address
- 1337 N. 116TH ST.
- City
- WAUWATOSA
- State
- WI
- ZIP
- 53226
- Mailing
- 12525 W. CAMERON AVE., BUTLER, WI 53007
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) Eye protection was not utilized while operating a pneumatic nailer exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. (a) Fall protection was not utilized by all employees while shingling a residential home. This exposed employees to an approximately 18' fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) The extension ladder used to access the roof did not extend at least three feet past the landing exposing employees to slipping and fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330924721.