MERIDIAN, ID —
OSHA Inspection: DOUG PRICE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DOUG PRICE in LOT 7 BLOCK 9 SILVER LEAF, MERIDIAN, ID 83646 (NAICS 238130). OSHA activity number 330968975.
Where did this inspection happen?
- Establishment
- DOUG PRICE
- Site address
- LOT 7 BLOCK 9 SILVER LEAF
- City
- MERIDIAN
- State
- ID
- ZIP
- 83646
- Mailing
- 631 CRITERION, MERIDIAN, ID 83642
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) Jobsite: On july 22, 2011 and times prior thereto employees using powered hand tools including pneumatic nail guns, did not wear any eye protection. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $1800
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:\r\n\r\n a) Jobsite: On July 22, 2011 and times prior thereto employees engaged in framing activities were exposed to an approximate 18 foot fall hazard to the ground below while setting trusses from the exterior top plate of the structure with out a fall protection system in place. b) Jobsite, second floor level: On July 22, 2011 and times prior thereto, employees were exposed to a fall hazard at the unprotected edge around the stairway where a guardrail system was not in place. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.503 A02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On July 22, 2011 and times prior thereto employees and the responsible person on site, did not acknowledge the fall hazards when performing framing activities which included setting trusses from the exterior top plate, and take the appropriate actions to eliminate or minimize the hazards. b) Jobsite: On July 22, 2011 and times prior thereto employees and the responsible person on site, did not acknowledge the fall hazard of the unprotected side or edge around the stairway, and take the appropriate action to eliminate or minimize the hazard. Note) Abatement certification IS required for this item. Note) Effective September 16, 2011 conventional methods for fall protection, per 29 CFR 1926.501(b)(13) shall be used. The alternative methods for fall protection in residential construction as described in STD 03-00-001 will no longer be acceptable.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge:\r\n\r\na) Jobsite: On July 22, 2011 and times prior thereto the stairway used for access to and from the second floor level did not have a stairrail and/or handrail in place.\r\n\r\nNote) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source