Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION INTERIORS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PRECISION INTERIORS in 4211 S. NATCHES COURT, ENGLEWOOD, CO 80110 (NAICS 337212). OSHA activity number 330970690.

Watch Precision Interiors — free Get an email when a new federal OSHA severe-injury report for Precision Interiors is published. One employer, no account, unsubscribe in one click.
Establishment
PRECISION INTERIORS
Site address
4211 S. NATCHES COURT
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
4211 S. NATCHES COURT, ENGLEWOOD, CO 80110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 2 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1400.00 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    1) On August 2, 2011, and at prior times, three unisaws in the shop were not guarded by an adjusting hood which would completely enclose the portion of the saw above the table and above the material.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2550

1910.22 A01

Other-than-serious 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1):  Place(s) of employment were not kept clean and orderly, or in a sanitary condition:    1) On August 2, 2011, and at prior times, floors, outlet boxes, and electrical conduits were covered in wood dust at and near the Weeke CNC machine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    1) On August 2, 2011, and at prior times, employees in the painting department who wore respiratory protection had not received medical evaluations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PRECISION INTERIORS's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330970690.