OSHA Inspection: POWER ENGINEERING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of POWER ENGINEERING COMPANY in 2525 S. DELAWARE ST., DENVER, CO 80223 (NAICS 333999). OSHA activity number 330984790.

Watch Power Engineering Company — free Get an email when a new federal OSHA severe-injury report for Power Engineering Company is published. One employer, no account, unsubscribe in one click.
Site address
2525 S. DELAWARE ST.
City
DENVER
State
CO
ZIP
80223
Mailing
2525 S. DELAWARE ST., DENVER, CO 80223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
43
Ownership type
A

4 citations on file for this inspection.

1910.23 D01

Other-than-serious 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $0.00 Reduced
29 CFR 1910.23(d)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standards railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder:      (a)  Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not ensure that open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The three air exchangers with open sided platform, eight feet above floor level, was not guarded by standard railings or the equivalent. This condition exposed employees to a fall hazard.    (b)  Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not ensure that open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The stairway access from the back door of the maintenance shop, was not guarded by standard railings or the equivalent. This condition exposed employees to a fall hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

1910.212 A01

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not protect employees from hazards created by operating a band saw with an unused portion of the blade unguarded, an unguarded trash compactor and a rotating shaft of a table saw motor. This condition exposed employees to amputation and crush hazards.      1)	Trash compactor  2)	Blue vertical band saw  3)             Rotating shaft on the table saw motor    Abatement Note: A feasible and acceptable abatement method to correct the hazard includes compliance with the American National Standards Institute, ANSI Z245.2, which requires an operating interlock on door, also an inspection of the trash compactor to ensure the interlock is functioning, and not permit an employee to operate the equipment unless the interlock and gate enclosure is functioning.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.305 B02 I

Serious Gravity 1 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $890.00 Reduced
29 CFR 1910.305(b)(2)(i):  All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy:     (a)  Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not protect employees from hazards created by uncovered junction box through which conductors enter. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $890
  • — Z (S) $1785

1910.303 G01

Serious Gravity 1 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1):  Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance od such equipment:    (a)  Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did ensure that working space about electric equipment rated 600 volts, nominal, or less had sufficient access to the electrical service panel. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0