Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CHIMNEY JACK

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHIMNEY JACK in 3494 W. HAYWARD PLACE, DENVER, CO 80211 (NAICS 238140). OSHA activity number 331074120.

Watch Chimney Jack — free Get an email when a new federal OSHA severe-injury report for Chimney Jack is published. One employer, no account, unsubscribe in one click.
Establishment
CHIMNEY JACK
Site address
3494 W. HAYWARD PLACE
City
DENVER
State
CO
ZIP
80211
Mailing
900 SOUTH ALCOTT STREET, DENVER, CO 80219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $900.00 Reduced
CFR 1926.20(b) (2):  The employer did not provide programs for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employer.    	(a)	Chimney Jack, 3494 W. Hayward Place, Denver, CO 80211:  On and before October 6, 2011, as the exposing and controlling employer for two employees working on a steep pitch roof, Chimney Jack failed to provide for regular inspections of the job site by a designated competent person. Condition exposed employees to fall hazards of over 12 feet due to a lack of adequate fall protection.    Abatement Note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification worksheet").
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
CFR 1926.501(b) (13):  Each employee engaged in residential construction activities 6 feet  (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems;    	(a)	Chimney Jack, 3494 W. Hayward Place, Denver, CO 80211:  On and before October 6, 2011, two employees of the controlling and exposing employer working on 12:12 pitch roof were not protected from falling by a system as described above.  Specifically, two employees were leaning near the edge of the roof to perform tuck pointing and masonry work on a chimney.  Condition exposed employees to fall hazards of approximately 12 feet.    Abatement Note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1926.503 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.    	(a)	Chimney Jack, 3494 W. Hayward Place, Denver, CO 80211:  On and before October 6, 2011, the employer did not provide each employee who conducted work on a roof with a training program to recognize fall hazards and minimize those hazards.   Condition exposed employees to fall hazards of approximately 12 feet.    Abatement Note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.     	(a)	Chimney jack, 3494 W. Hayward Place, Denver, CO 80211:  On and before October 6, 2011, the controlling and exposing employer did not ensure that a portable extension ladder used to gain access to the upper landing where work was taking place extended at least 3 feet above the landing surface. Condition exposed employees to fall hazards of approximately 12 feet as they accessed the landing using the ladder.     Abatement Note:  Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

View CHIMNEY JACK's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331074120.