CHICAGO, IL —
OSHA Inspection: MAXWELL SERVICES, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MAXWELL SERVICES, INC. in 5921 S. WABASH AVENUE, CHICAGO, IL 60628 (NAICS 236118). OSHA activity number 331084855.
Where did this inspection happen?
- Establishment
- MAXWELL SERVICES, INC.
- Site address
- 5921 S. WABASH AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60628
- Mailing
- 3130 S. KOLIN AVENUE, CHICAGO, IL 60623
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling or certification: a) On or about October 7, 2011, at the jobsite located at 5921 S. Wabash Avenue, Chicago, IL - the employer did not ensure that the temporary electrical wiring on the jobsite was free from recognized hazards, in that an electrical box made to be attached to a structure was laying on the floor, thereby exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $1800
1926.403 I02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(i)(2)(I): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means: (A) by location in a room, vault, or similar enclosure that is accessible only to qualified persons; (B) by partitions or screens so arranged that only qualified persons will have access to the space within reach of the live parts; (C) by location on a balcony, gallery, or platform so elevated and arranged as to exclude unqualified persons, (D) by elevation of 8 feet or more above the floor or other working surfaces and so installed as to exclude unqualified persons: a) On or about October 7, 2011, at the jobsite located at 5921 S. Wabash Avenue, Chicago, IL. - employees were using receptacles and light switches that were not provided with covers or face plates to protect against accidental contact, thereby exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236118)
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
SYRACUSE, NY—2026-07-14
EMPIRE BUILDERS OF CNY, INC.
RENTON, WA—2026-07-14
WA317992055 - JCC INVESTMENT GROUP LLC
RIVERTON, NJ—2026-07-14
JBF CONSTRUCTION LLC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331084855.