Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHANE DEMLER MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHANE DEMLER MASONRY, INC. in 4002 SAMUELSON, SANDPOINT, ID 83864 (NAICS 238140). OSHA activity number 331104604.

Watch Shane Demler Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Shane Demler Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4002 SAMUELSON
City
SANDPOINT
State
ID
ZIP
83864
Mailing
P.O. BOX 232, NEWTON, UT 84327
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Deleted Repeat Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $0.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:     (a) On the north side: On or about 12/6/2011, and at times prior thereto, employees working on the second level deck of the tubular welded frame scaffold  that was not completely decked, it had gaps of 4 inches on each side, were exposed to a fall hazard.     Note: Abatement certification and documentation are required.      The employer, Shane Demler Masonry, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(b)(1)which was contained in OSHA inspection Number 311582779 Citation number 1, item number 2a and was affirmed as a final order on 06/12/2009, with respect to a workplace located at 900 Environmental Way, Idaho Falls, ID 83401.
Recent events (2)
  • — I (R) $0
  • — Z (R) $3600

1926.451 E01

Deleted Repeat Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): Scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used. Crossbraces were used as a means of access:    a) On the north side: on or about 12/6/2011, and at times prior thereto, employees were not provided with a safe means of accessing the second and third level decks of the tubular welded frame scaffold.    Note: Abatement certification and documentation ARE required.    The employer, Shane Demler Masonry, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(e)(1)which was contained in OSHA inspection Number 311582779 Citation number 1, item number 3 and was affirmed as a final order on 06/12/2009, with respect to a workplace located at 900 Environmental Way, Idaho Falls, ID 83401.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1926.451 G01

Deleted Repeat Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1): Employee's on a scaffold platform more than 10 feet (3.1 m) above a lower level were not protected from falling to a lower level.  Fall protection for scaffolding must meet requirements specified in 29 CFR 1926.451(g)(1)(i) through (vii):     a) On the north side scaffolds: On or about 12/6/2011, and at times prior thereto, employees working on the tubular welded frame scaffolding at a height of approximately 11.5 feet were not protected by guard rails and end rails.     Note: Abatement certification and documentation are required.    The employer, Shane Demler Masonry, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1) which was contained in OSHA inspection Number 311582779 Citation number 1, item number 2b and was affirmed as a final order on 06/12/2009, with respect to a workplace located at 900 Environmental Way, Idaho Falls, ID 83401.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1926.153 O

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was  possible, precautions against such damage were not taken:    a) On the southeast corner: on or about 12/6/2011, and at times prior thereto, the 500 gallon LP Gas tank on the concrete slab was not protected from damage by the GEHL powered industrial truck when loading materials on the scaffold.    Note: Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SHANE DEMLER MASONRY, INC.'s full OSHA safety record →