MARTINS FERRY, OH —
OSHA Inspection: JAMES LOUIS PLASTERING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAMES LOUIS PLASTERING in 709 BROADWAY STREET, MARTINS FERRY, OH 43935 (NAICS 238140). OSHA activity number 331110585.
Where did this inspection happen?
- Establishment
- JAMES LOUIS PLASTERING
- Site address
- 709 BROADWAY STREET
- City
- MARTINS FERRY
- State
- OH
- ZIP
- 43935
- Mailing
- 405 NORTH 7TH STREET, MARTINS FERRY, OH 43935
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and verticalsurface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrailsystems, safety net systems, or personal fall arrest systems. a) At the site, an employee was working on a wooden platform at a height of 7 feet without the use of fall protection.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the frontuprights and the guardrail supports as follows: a) At the site, employees were working on tubular welded frame scaffolds that were not properly planked.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof,which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members sothat the erected scaffold is always plumb, level, and square. All brace connections shall be secured. a) At the site, employees were working from tubular welded frame scaffolds that were not equipped with an adequate amount of cross bracing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sillsor other adequate firm foundation. a) At the site, employees were working on a tubular welded frame scaffold that did not have a base plate on one of the scaffold's poles.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331110585.