OSHA Inspection: JAMES LOUIS PLASTERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAMES LOUIS PLASTERING in 709 BROADWAY STREET, MARTINS FERRY, OH 43935 (NAICS 238140). OSHA activity number 331110585.

Watch James Louis Plastering — free Get an email when a new federal OSHA severe-injury report for James Louis Plastering is published. One employer, no account, unsubscribe in one click.
Site address
709 BROADWAY STREET
City
MARTINS FERRY
State
OH
ZIP
43935
Mailing
405 NORTH 7TH STREET, MARTINS FERRY, OH 43935
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1926.501(b)(1):     "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and verticalsurface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrailsystems, safety net systems, or personal fall arrest systems.      a)  At the site, an employee was working on a wooden platform at a height of 7 feet without the use of fall protection.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the frontuprights and the guardrail supports as follows:      a)  At the site, employees were working on tubular welded frame scaffolds that were not properly planked.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.452 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(c)(2):     Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof,which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members sothat the erected scaffold is always plumb, level, and square. All brace connections shall be secured.      a)  At the site, employees were working from tubular welded frame scaffolds that were not equipped with an adequate amount of cross bracing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sillsor other adequate firm foundation.    a) At the site, employees were working on a tubular welded frame scaffold that did not have a base plate on one of the scaffold's poles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0