OSHA Inspection: CARNEGIE FEDERAL BODY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CARNEGIE FEDERAL BODY, LLC in 9500 BROOKPARK RD., CLEVELAND, OH 44129 (NAICS 811111). OSHA activity number 331112235.

Watch Carnegie Federal Body, LLC — free Get an email when a new federal OSHA severe-injury report for Carnegie Federal Body, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9500 BROOKPARK RD.
City
CLEVELAND
State
OH
ZIP
44129
Mailing
9500 BROOKPARK RD., CLEVELAND, OH 44129
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $1800.00 Reduced
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.    On or about 12/8/11, lift truck training had not been provided in the last 3 years.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3600

1910.179 J03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.179(j)(3):   A complete periodic inspection of crane(s) had not been conducted in the past 12 months:    On or about 12/8/11, annual inspections, on two 3-ton overhead cranes, located on the workroom floor, were not performed.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.215(a)(4):     Work rests were not adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which might have caused wheel breakage:    On or about 12/8/11, the work rest, on the right side, of the Standard Electrical Tool Co. Pedestal Grinder, was not adjusted as required.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.215 B09

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9):     The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top  exceeded one-fourth inch:    On or about 12/8/11, the tongue guard on the following equipment was not adjusted as required or missing:    a.  Baldor Bench Grinder - 1 1/4" opening - tongue guard missing;    b.  Standard Electrical Tool Co. Pedestal Grinder - 1/2" opening on left side; 1/2" opening on right side.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.1200(e)(1):     Employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning,material safety data sheets, and employee information and training will be met, and which also includes the following:    On and before 12/8/11, the employer had not developed a Hazard Communication Program for chemicals such as, but not limited to: gasoline, paint, and thinners.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.1200 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1):     The employer did not have a material safety data sheet in the workplace for each hazardous chemical which they use.    On and before 12/8/11, the employer did not maintain material safety data sheets for chemicals such as, but not limited to:  gasoline, paint, and thinners.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:          On and before 12/8/11, employees were not provided training on hazardous chemicals  such as, but limited to:  gasoline, paint, and thinners.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 A

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $0.00 Reduced
DESCRIPTION  29 CFR �1904.29(a): A Log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses, (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment:    On or about 12/8/11, the OSHA 300, 300-A, and 301 were not maintained for the years 2009, 2010, and 2011.
Recent events (2)
  • — I (O) $0
  • — Z (O) $600

1910.157 G02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(g)(2):  The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:     Employees designated to use fire extinguishers, were not trained annually.    Note:  Employer may exercise one of the following options.    1)  Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75' to the nearest extinguisher for Class A fires and 50" to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g).  The other sections of 29 CFR also apply.    2)  Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g).  The other sections of 29 CFR also apply.    3)  Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b).  Utilizing this option exempts the employer from the requirements of 29 CFR 190.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 190.106/107 related to use/storage of flammable/combustible liquids).  If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable i(inspection, maintenance, and testing of equipment).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0