Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARROLL'S TRUCK PARTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CARROLL'S TRUCK PARTS in 2064 NAZOR ROAD, GALION, OH 44833 (NAICS 423140). OSHA activity number 331112599.

Watch Carroll'S Truck Parts — free Get an email when a new federal OSHA severe-injury report for Carroll'S Truck Parts is published. One employer, no account, unsubscribe in one click.
Site address
2064 NAZOR ROAD
City
GALION
State
OH
ZIP
44833
Mailing
2064 NAZOR ROAD, GALION, OH 44833
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423140
Employees
5
Ownership type
A

8 citations on file for this inspection.

1910.157 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.157(c)(4):     Portable fire extinguishers were not maintained in a fully charged and operable condition:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to ensure that portable fire extinguishers on site are maintained in a fully charged and in operable condition, exposing employees to hazards associated with fire suppression and operation of fire suppression equipment.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.157 E02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer did not ensure that portable fire extinguishers on site were inspected monthly in order to make sure that extinguishers were fully charged and in operable condition, exposing employees to hazards associated with fire suppression and operation of fire suppression equipment.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(g)(2):   The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to provide employees with an educational program upon initial employment and at least annually thereafter on the use of portable fire extinguishers and the hazards associated with incipient stage fire fighting, exposing employees to hazards associated with fire suppression and operation of fire suppression equipment.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer did not ensure that employees, operating Volvo BM (Type L90, Cab Serial # 16568) and FiatAllis (Model R15B/2T, Serial # 595535) powered industrial vehicles, were competent to complete the task, thereby exposing employees to struck-by, caught in between, and tip over hazards. The employer did not ensure that each powered industrial vehicle operator received formal instructions and practical training on how to operate a powered industrial vehicle, as well as the operators performance was not evaluated.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1910.178 P01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(1):     Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition:    A.	Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to remove the powered industrial vehicle Volvo BM (Type L90, Cab Serial # 16568) from use based on mechanical defects such as, but not limited to, broken rear lights. Employees were exposed to struck-by and caught in between hazards.    B.	Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to remove the powered industrial vehicle FiatAllis (Model R15B/2T, Serial # 595535) from use based on mechanical defects such as, but not limited to, transmission oil leak and broken rear lights. Employees were exposed to struck-by and caught in between hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.252(a)(3)(i):     Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which when subjected to heat, might produce flammable or toxic vapors:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to ensure that oxygen and propane cylinders were completely empty in order to make certain that there are no flammable materials left inside the cylinders prior to cutting them with a torch and a DeWalt 18V reciprocating saw, exposing employees to fire and explosion hazards.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.253 B02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(2)(iv):     Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer did not ensure that valve protection caps were in place on oxygen and acetylene cylinders that were stored in the trailer on site. Employees were exposed to a risk of serious injuries if the cylinders fell over, the valve assemblies were knocked off, and the escaping gas ignited, or if the escaping gas propelled the cylinders into the employees.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:    Carrolls Truck Parts, located at 2064 Nazor Rd., Galion, OH: On or about January 17, 2012, the employer failed to ensure that oxygen cylinders that, stored in the trailer on site, were separated from acetylene cylinders by a minimum distance of 20 feet. The oxygen and propane cylinders were stored close to each other exposing employees to a fire hazard.    No additional abatement information is needed for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331112599.