CLEVELAND, OH —
OSHA Inspection: ONE SOURCE BUILDING RESTORATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ONE SOURCE BUILDING RESTORATION, INC. in 710 JEFFERSON AVENUE, CLEVELAND, OH 44113 (NAICS 238140). OSHA activity number 331901181.
Where did this inspection happen?
- Establishment
- ONE SOURCE BUILDING RESTORATION, INC.
- Site address
- 710 JEFFERSON AVENUE
- City
- CLEVELAND
- State
- OH
- ZIP
- 44113
- Mailing
- 21990 ROBERTS AVENUE, CLEVELAND, OH 44123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 D01
- Issued
- Penalty
- Initial $4200.00 · Current $2940.00 Reduced
General-duty citation text
29 CFR 1926.451(d)(1): All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices shall rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist, whichever is greater): Parapet clamps supporting a two-point suspension scaffold rested on an unreinforced masonry parapet wall.
Recent events (2)
- — I (S) $2940
- — Z (S) $4200
1926.451 D03 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(d)(3)(i): Before the scaffold is used, direct connections shall be evaluated by a competent person who shall confirm, based on the evaluation, that the supporting surfaces are capable of supporting the loads to be imposed: Before the two-point suspension scaffold was used on 01/24/2012, no one looked at the scaffold, its direct connections, or the parapet wall for its supporting capacity.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 D03 IX
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(d)(3)(ix): Tiebacks shall be secured to a structurally sound anchorage on the building or structure. Sound anchorages include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit: Tiebacks were not installed on the two-point suspension scaffold before its use on 01/24/2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G03 IV
- Issued
- Penalty
- Initial $3600.00 · Current $2520.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system: On 01/24/2012, each life line (2 total) used by employees was attached to the same point of anchorage, an inside masonry wall.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: Employees were not trained on the correct use and operations for using SAFEWAZE rope grabs. Instructions imprinted on the metal rope grab stated "to be used with 3 foot lanyard". The lanyards used by the employees measured 5 feet 3 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D20
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(20): The employer shall provide for prompt rescue of employees in the event of a fall or shall assure that employees are able to rescue themselves: On 01/24/2012, there was no rescue plan in place for at least one suspended employee who was not able to reach a work level independently in order to self-rescue.
Recent events (2)
- — I (O) $0
- — Z (S) $3600
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.103 as set forth in 29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use: There was no written Respiratory Protection program for masons using 1/2 mask, negative-pressure respirators during operations that include working with products containing silica and/or portland cement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331901181.