OSHA Inspection: EVANS ELECTRIC LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of EVANS ELECTRIC LLC in 3622 S. STATE ST, CHICAGO, IL 60609 (NAICS 237130). OSHA activity number 331907162.

Watch Evans Electric LLC — free Get an email when a new federal OSHA severe-injury report for Evans Electric LLC is published. One employer, no account, unsubscribe in one click.
Establishment
EVANS ELECTRIC LLC
Site address
3622 S. STATE ST
City
CHICAGO
State
IL
ZIP
60609
Mailing
4146 WARREN AVE., HILLSIDE, IL 60162
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1260.00 Reduced
29 CFR 1926.403(i)(2)(I):   Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:  (A) by location in a room, vault, or similar enclosure that is accessible only to qualified persons; (B) by partitions or screens so arranged that only qualified persons will have access to the space within reach of the live parts; (C) by location on a balcony, gallery, or platform so elevated and arranged as to exclude unqualified persons, (D) by elevation of 8 feet or more above the floor or other working surfaces and so installed as to exclude unqualified persons:    a) On or about January 31, 2012, at the above addressed jobsite, temporary wiring was not protected from accidental contact, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $1800

1926.405 A02 II B

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(B):  Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices attheir ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall befastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that suppliesreceptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.    a.  On or about January 31, 2012, at the above addressed jobsite, conductors were not protected from physical damage, thereby exposing employees to electric shocks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View EVANS ELECTRIC LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331907162.