On , OSHA opened a planned safety inspection of WILLIAM HYLAND in 308 HADDON AVE, WESTMONT, NJ 08108 (NAICS 238160). OSHA activity number 331912444.
Where did this inspection happen?
- Establishment
- WILLIAM HYLAND
- Site address
- 308 HADDON AVE
- City
- WESTMONT
- State
- NJ
- ZIP
- 08108
- Mailing
- 712 LEES AVE, COLLINGSWOOD, NJ 08108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G01
- Issued
- Penalty
- Initial $3600.00 · Current $2160.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected fromfalling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employeeson each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs,and other elevated surfaces are set forth in subpart M of this part. a)Scaffold: employees working from scaffolds in excess of 10 feet were not protected by any means on or about 2/10/12.
Recent events (2)
- — I (S) $2160
- — Z (S) $3600
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): 29 CFR 1926.20 (b)(2) The employer did not develop an accident prevention program, that provided for frequent and regular inspections of the job sites, materials, and equipment, to be made by competent persons designated by the employer. a)Front of building: Frequent and regular inspections were not performed by a competent person on site which would have addressed hazards present at the jobsite on or about 2/10/12. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331912444.