CORONADO, CA —
OSHA Inspection: ZENETEX
Unprogrammed Other inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Other health inspection of ZENETEX in BLDG. 94 NAS NORTH ISLAND, CORONADO, CA 92178 (NAICS 488190). OSHA activity number 331915660.
Where did this inspection happen?
- Establishment
- ZENETEX
- Site address
- BLDG. 94 NAS NORTH ISLAND
- City
- CORONADO
- State
- CA
- ZIP
- 92178
- Mailing
- 950 HERNDON PKWY STE 350, HERNDON, VA 20170
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 70
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $3500.00 Reduced
0360
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm to employees in that the employer failed to put into place Safety and Health programs, policies, and procedures to protect employees from the hazards of Beryllium. Located in Bldg. 94, Hangar, Mezzanine, and Administration Offices, the employer failed to put into place Safety and Health programs, policies, and procedures to protect employees from the hazards of beryllium, which is likely to cause death and/or serious physical harm to employees. AMONG OTHER METHODS, FEASIBLE AND ACCEPTABLE METHODS TO CORRECT THE HAZARD WOULD BE TO FOLLOW THE PROVISIONS OF: ANSI standard is A37.29-1970 and DHHS (NIOSH Be Alert) Publication Number 2011 107 dated Feb. 2011 having feasible abatement methods for reducing this hazard include but are not limited to: 1. Institute a written effective Beryllium Dust and Exposure Control Program that details procedures for controlling beryllium dust contamination. The written program must indicate effective engineering controls, work practices, training, and housekeeping procedures. 2. Periodically evaluate the written program's effectiveness, including frequent and regular inspections by competent designated persons, HVAC balancing of the North Administration Offices, as well as institute changes when the written program is deemed ineffective. 3. Discontinue sanding and grinding in the open bays and conduct sanding and grinding operations in fully enclosed exhaust booths and isolation rooms that effectively capture all dusts generated by the operations. 4. Institute routine maintenance of ventilation engineering controls (vacuum tools, exhaust booths, etc.) to capture beryllium dusts generated during sanding and grinding operations. 5. Discontinue work practices of dry sweeping or other procedures that recirculate dusts into the air. 6. Institute effective use of vacuuming of work surfaces where dusts may have accumulated. 7. Require use of respirators and skin protective PPE to prevent exposure to beryllium dusts during work operations and clean up. 8. Require use of gloves while working in the zone of danger including desks and computer stations. 9. Evaluate and clean up dust accumulation throughout the building as well as the general HVAC system in the North Administration Office side of Bldg. 94. 10. Require employees to wash hands and faces before breaks and shower at the end of the work shift leaving at work site soiled work clothing or uniforms for laundering. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with beryllium dusts.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.141 G02
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $3500.00 Reduced
1591C141
General-duty citation text
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials: a) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium. b) At Bldg. 94, South lunch room, underneath microwave - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. c) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. d) At Bldg. 94, North lunchroom, top of South side Gatorade dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. e) At Bldg. 94, Contractor room, refrigerator door handle - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium. f) At Bldg. 94, Contractor room, top of refrigerator - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with ingesting toxic materials.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.141 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591C141
General-duty citation text
29 CFR 1910.141(g)(4): Food or beverages were stored in area(s) exposed to toxic material(s): a) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium. b) At Bldg. 94, South lunch room, underneath microwave - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. c) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. d) At Bldg. 94, North lunchroom, top of South side Gatorade dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. e) At Bldg. 94, Contractor room, refrigerator door handle - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium. f) At Bldg. 94, Contractor room, top of refrigerator - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with ingesting toxic materials.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 H01
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $3500.00 Reduced
1591
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces shall be maintained as free as practicable of accumulations of lead: a) At Bldg. 94, Quickie shop, top of Dustron grind booth 039809 - On or about 2/16/12, lead dusts were allowed to accumulate. b) At Bldg. 94, Quickie shop, top of panel of Dustron 039809 grind booth - On or about 2/16/12, lead dusts were allowed to accumulate. c) At Bldg. 94, Wing Shop, Dustron grind booth floor - On or about 2/16/12, lead dusts were allowed to accumulate. d) At Bldg. 94, Wing shop, top of black metal cabinet - On or about 2/16/12, lead dusts were allowed to accumulate. e) At Bldg. 94, Bldg. 94, Wing shop, cart - On or about 2/16/12, lead dusts were allowed to accumulate. f) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, lead dusts were allowed to accumulate. g) At Bldg. 94, South lunch room, underneath microwave, by window - On or about 2/16/12, lead dusts were allowed to accumulate. h) At Bldg. 94, E-37 area adjacent to emergency shower, top of cabinet - On or about 2/16/12, lead dusts were allowed to accumulate. i) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, lead dusts were allowed to accumulate. j) At Bldg. 94, North lunchroom, south side Gatorade dispenser - On or about 2/16/12, lead dusts were allowed to accumulate. k) Bldg. 94, Hangar, Near column F-19, Top of electrical panel adjacent to 5-3-LP-1-02 - On or about 4/10/12, lead dusts were allowed to accumulate. l) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, lead dusts were allowed to accumulate. m) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, lead dusts were allowed to accumulate. n) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, lead dusts were allowed to accumulate. o) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, lead dusts were allowed to accumulate. p) At Bldg. 94, Mezzanine, Top of red tool box - On or about 4/10/12, lead dusts were allowed to accumulate. q) At Bldg. 94, Mezzanine, Fencing above the Bonding shop - On or about 4/10/12, lead dusts were allowed to accumulate. r) At Bldg. 94, First floor, Adjacent to stairs, Left of electrical panel L4.5 - On or about 4/10/12, lead dusts were allowed to accumulate. s) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, lead dusts were allowed to accumulate. t) At Bldg. 94, E-37 floor below emergency shower - On or about 4/10/12, lead dusts were allowed to accumulate. u) At Bldg. 94, Middle quad desk, MSDS binder - On or about 4/10/12, lead dusts were allowed to accumulate. v) At Bldg. 94, Middle quad desk, Employee clock out computer keyboard - On or about 4/10/12, lead dusts were allowed to accumulate. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with lead.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.1025 H02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1910.1025(h)(2)(ii): Shoveling, sweeping or brushing methods were used to remove lead accumulations where vacuuming or other equally effective methods were available and feasible: a) At Bldg. 94 - On or about 4/10/12, and at times prior thereto, dry sweeping was performed throughout the hangar including the open bays of the center barrel area, disassembly area, Wing shop, Quickie shop, mezzanine, and lunch rooms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 K01
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $3500.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(k)(1): Surfaces were not maintained as free as practicable of accumulations of cadmium: a) At Bldg. 94, Quickie shop, top of Dustron grind booth 039809 - On or about 2/16/12, cadmium dusts were allowed to accumulate. b) At Bldg. 94, Quickie shop, top of panel of Dustron 039809 grind booth - On or about 2/16/12, cadmium dusts were allowed to accumulate. c) At Bldg. 94, Wing Shop, Dustron grind booth floor - On or about 2/16/12, cadmium dusts were allowed to accumulate. d) At Bldg. 94, Wing shop, top of black metal cabinet - On or about 2/16/12, cadmium dusts were allowed to accumulate. e) At Bldg. 94, Bldg. 94, Wing shop, cart - On or about 2/16/12, cadmium dusts were allowed to accumulate. f) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, cadmium dusts were allowed to accumulate. g) At Bldg. 94, South lunch room, underneath microwave, by window - On or about 2/16/12, cadmium dusts were allowed to accumulate. h) At Bldg. 94, E-37 area adjacent to emergency shower, top of cabinet - On or about 2/16/12, cadmium dusts were allowed to accumulate. i) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, cadmium dusts were allowed to accumulate. j) At Bldg. 94, North lunchroom, south side Gatorade dispenser - On or about 2/16/12, cadmium dusts were allowed to accumulate. k) At Bldg. 94, Hangar, Near column F-19, Top of electrical panel adjacent to 5-3-LP-1-02 - On or about 4/10/12, cadmium dusts were allowed to accumulate. l) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, cadmium dusts were allowed to accumulate. m) At Bldg. 94, Mezzanine, Eyewash - On or about 4/10/12, cadmium dusts were allowed to accumulate. n) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, cadmium dusts were allowed to accumulate. o) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, cadmium dusts were allowed to accumulate. p) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, cadmium dusts were allowed to accumulate. q) At Bldg. 94, Mezzanine, Top of red tool box - On or about 4/10/12, cadmium dusts were allowed to accumulate. r) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, cadmium dusts were allowed to accumulate. s) At Bldg. 94, Mezzanine, Fencing above the Bonding shop - On or about 4/10/12, cadmium dusts were allowed to accumulate. t) At Bldg. 94, First floor, Adjacent to stairs, Left of electrical panel L4.5 - On or about 4/10/12, cadmium dusts were allowed to accumulate. u) At Bldg. 94, Mezzanine, Hallway ledge adjacent to fire extinguisher - On or about 4/10/12, cadmium dusts were allowed to accumulate. v) At Bldg. 94, Mezzanine, Hallway, Top of door frame - On or about 4/10/12, cadmium dusts were allowed to accumulate. w) At Bldg. 94, Contractor break room, refrigerator door handle - On or about 4/10/12, cadmium dusts were allowed to accumulate. x) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, cadmium dusts were allowed to accumulate. y) At Bldg. 94, E-37 floor below emergency shower - On or about 4/10/12, cadmium dusts were allowed to accumulate. z) At Bldg. 94, Middle quad desk, MSDS binder - On or about 4/10/12, cadmium dusts were allowed to accumulate. aa) At Bldg. 94, Middle quad desk, Employee clock out computer keyboard - On or about 4/10/12, cadmium dusts were allowed to accumulate. Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with cadmium dusts.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.1027 K05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
C141
General-duty citation text
29 CFR 1910.1027(k)(5): Shoveling, dry or wet sweeping and brushing were used where vacuuming or other methods that minimize the likelihood of cadmium becoming airborne had not been tried and/or had been found effective: a) At Bldg. 94 - On or about 4/10/12, and at times prior thereto, dry sweeping was performed throughout the hangar including the open bays of the center barrel area, disassembly area, Wing shop, Quickie shop, mezzanine, and lunch rooms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 488190)
TRAVERSE CITY, MI—2026-07-14
UNIFI AVIATION LLC
VANDALIA, OH—2026-07-08
SIERRA NEVADA CORPORATION
ASPEN, CO—2026-06-17
ATLANTIC AVIATION-MONTROSE LLC
GULF SHORES, AL—2026-06-17
TREGO/DUGAN AVIATION OF GRAND ISLAND, INC.
LOS ANGELES, CA—2026-06-12
UNITED AIRLINES
More inspections in CA
EL CAJON, CA—2026-07-16
GRANITE AND MARBLE CONCEPTS INC.
LIVERMORE, CA—2026-07-16
RJMS CORPORATION
BAKERSFIELD, CA—2026-07-16
MAYORGA FARM LABOR SERVICES
SANTA PAULA, CA—2026-07-16
AHUATZI PRODUCE INC.
SANTA PAULA, CA—2026-07-16
MENDOZA PRODUCE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331915660.