SCARSDALE, NY —
OSHA Inspection: PETER BOBER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PETER BOBER in 24 RICHBELL RD., SCARSDALE, NY 10583 (NAICS 238160). OSHA activity number 332793181.
Where did this inspection happen?
- Establishment
- PETER BOBER
- Site address
- 24 RICHBELL RD.
- City
- SCARSDALE
- State
- NY
- ZIP
- 10583
- Mailing
- 38 ROSS DRIVE, YORKTOWN HEIGHTS, NY 10598
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.404 B01 I
- Issued
- Penalty
- Initial $3000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. location: interior of house on or about: 02/29/12 a) Employees were using electrical equipment, including but not limited to a DeWalt circular saw, while engaged in carpentry work. The employees were not provided with GFCI protection or an assured equipment grounding conductor program. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $3000
1926.451 G01
- Issued
- Penalty
- Initial $4200.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: location: front of house on or about: 2/29/12 a) Employees were working from a bracket scaffold without fall protection. The employees were exposed to a fall of up to 17 feet. location: rear of house on or about: 2/29/12 b) Employees were working from a pump jack scaffold without fall protection. The employees were exposed to a fall of up to 17 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2000
- — Z (S) $4200
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: entire site on or about: 2/29/12 a) Employees were working from pump jack and bracket scaffolding. The employees were not provided with scaffold safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: location: entire site on or about: 2/29/12 a) Employees erected a pump jack and bracket scaffolding. The employees were not provided with scaffold safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Penalty
- Initial $3000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. location: rear of house on or about: 2/29/12 b) Employees were working from a pump jack scaffold without fall protection. The pump jack scaffold was not bracecd at the bottom of the poles. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $3000
1926.501 B13
- Issued
- Penalty
- Initial $4200.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. location: entire house on or about: 2/29/12 a) Employees, engaged in residential carpentry, were not using fall protection. The employees were exposed to a fall of up to 23 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2000
- — Z (S) $4200
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. location: entire site on or about: 2/29/12 a) Employees, engaged in residential carpentry, were not protected from falling up to 23 feet. The employees were not provided with any fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01 II
- Issued
- Penalty
- Initial $2400.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: One stairrail system along each unprotected side or edge: Note: When the top edge of a stairrail system also serves as a handrail, paragraph (c)(7) of this section applies. location: stairs between 1st and 2nd floor on or about: 2/29/12 a) Employees were using the stairway for acess/egress. The open sided stairway was only provided with a stairrail on one side. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2400
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards: location: entire site on or about: 2/29/12 a) Employees were using stairways and Werner extension ladders while engaged in residential carpentry. The employees were not provided with stairway and ladder safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Penalty
- Initial $1800.00 · Current $200.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed: location: exterior of house on or about: 2/29/12 a) Employees were using a Werner portable metal extension ladder to access the bracket scaffold. The lanyard, connecting the 2 flys of the ladder, was missing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $200
- — Z (S) $1800
1926.405 J01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Support. Fixtures, lampholders, rosettes, and receptacles shall be securely supported. A fixture that weighs more than 6 pounds (2.72 kg) or exceeds 16 inches (406 mm) in any dimension shall not be supported by the screw shell of a lampholder. location: interior of house on or about: 02/29/12 a) Employees were using unsecured electrical outlets to power electrical equipment, including a DeWallt circular saw, while engaged in carpentry work. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332793181.