OSHA Inspection: PERFORMANCE WELDING INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PERFORMANCE WELDING INC in 1300 E NORTH AVE, LITTLE CHUTE, WI 54140 (NAICS 332999). OSHA activity number 332805373.

Watch Performance Welding INC — free Get an email when a new federal OSHA severe-injury report for Performance Welding INC is published. One employer, no account, unsubscribe in one click.
Site address
1300 E NORTH AVE
City
LITTLE CHUTE
State
WI
ZIP
54140
Mailing
1300 E NORTH AVE, LITTLE CHUTE, WI 54140
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
44
Ownership type
A

1 citation on file for this inspection.

1910.212 A03 II

Serious Gravity 5 5 instances 10 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1050.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) The Cincinnati 175 PF x 10 FT press brake, Serial No. 53976, point of operation was not guarded to prevent any part of the operator's body within the hazardous area during the the hazardous downstroke cycle.     b) The Cincinnati 6' 60 ton press brake, Serial No. 53655, point of operation was not guarded to prevent any part of the operator's body within the hazardous area during the hazardous downstroke cycle.     c) The Cincinnati 350 CB x 12 FT press brake, Serial No. xx814, point of operation was not guarded to prevent any part of the operator's body within the hazardous area during the hazardous downstroke cycle.     d) The Cincinnati 90 CBII x 10 FT press brake, Serial No. 50962, point of operation was not guarded to prevent any part of the operator's body within the hazardous area during the hazardous downstroke cycle.     e) The Mitsubishi 4000 W Laser LVP 1 processing head was not shielded with the interlocking gate when the laser was in operation when smaller metal sheets were cut, exposing the operators to burn and point of operation hazards.     Abatement Certfication and Abatement Documentation Required.