Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JEFFREY A HIGDON CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JEFFREY A HIGDON CONSTRUCTION in 530 NE TOMAHAWK ISLAND DRIVE SLIP A-1, PORTLAND, OR 97217 (NAICS 236115). OSHA activity number 332812197.

Watch Jeffrey A Higdon Construction — free Get an email when a new federal OSHA severe-injury report for Jeffrey A Higdon Construction is published. One employer, no account, unsubscribe in one click.
Site address
530 NE TOMAHAWK ISLAND DRIVE SLIP A-1
City
PORTLAND
State
OR
ZIP
97217
Mailing
P.O. BOX 309, FOREST GROVE, OR 97116
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.106 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $1125.00 Reduced
29 CFR 1926.106(a):     Employee(s) working over or near water where the danger of drowning existed, were not provided with U.S. Coast Guard approved life jacket(s) or buoyant work vest(s)    OR in the alternative      29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    Floating Home Project, Tomahawk Island-    (a) Workers on the floating home's unguarded 2nd floor sun deck were not protected from falls of 9' 8" and were not wearing buoyant work vest while installing "deck curbing" exposing them to falls onto the dock below or into the Columbia River.
Recent events (2)
  • — I (S) $1125
  • — Z (S) $2250

1926.106 D

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.106(d):     A lifesaving skiff was not immediately available at locations where employees were working over or adjacent to water:    Floating Home Project- Tomahawk Island-  (a) There was no lifesaving skiff at the worksite to provide immediate rescue for workers exposed to falling into the Columbia River.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.106 C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.106(c):     Ring buoys with at least 90 feet of line were not provided and readily available for emergency rescue operations:    Floating Home Project, Tomahawk Island  (a) There was no ring buoys located at the work site next to the Columbia River, for workers constructing the sun deck.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1926.403(i)(2)(i):     Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    Floating Home Project, Tomahawk Island-    (a) Live parts of the duplex receptacle, located on the 1st floor, had exposed parts of 110 volts nominal.      (b) Live conductors of branch circuit were exposed on the 1st floor.    (c) Light fixture located at on the wall next to the stairs had exposed live parts of 110 volts nominal.    (d) Live parts of the light switch, located on the 1st floor, had exposed 110 volts nominal.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.1052 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $900.00 Reduced
29 CFR 1926.1052(c)(1):     Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge:    Floating Home Project, Tomahawk Island-    (a) The stairway leading to the 2nd floor did not have any handrails exposing employees to falls of approx. 8 feet.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332812197.