OSHA Inspection: KNIGHT REFRIGERATED, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KNIGHT REFRIGERATED, LLC in 1795 NORTH HOLMES, IDAHO FALLS, ID 83401 (NAICS 484121). OSHA activity number 332822345.

Watch Knight Refrigerated, LLC — free Get an email when a new federal OSHA severe-injury report for Knight Refrigerated, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1795 NORTH HOLMES
City
IDAHO FALLS
State
ID
ZIP
83401
Mailing
1795 NORTH HOLMES, IDAHO FALLS, ID 83401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
154
Ownership type
A

7 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1200.00 Reduced
29 CFR 1910.106(e)(6)(ii): Class I liquids were dispensed into containers where the nozzle and container were not electrically interconnected.     a) South wall of maintenance shop: On March 14, 2012 and at times prior thereto transferring of methanol, a Class 1B flammable liquid, from one barrel to another was done without the protection of grounding or bonding to minimize the hazard of static electricity.    Note ) Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2295

1910.37 B02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2) Each exit was not clearly visible and marked by a sign reading "Exit":    a) Wash bay: On March 14, 2012 and at times prior thereto the exit sign above the exit door had been removed.      Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:    a) Maintenance shop: On March 14, 2012 and at times prior thereto employees operating powered industrial trucks (forklifts) had not evaluated and certified by the employer to ensure safe operation and material handling.        Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C01

Deleted Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment will be isolated from the energy source and rendered inoperative:    a) Maintenance shop: On March 14, 2012 and at times prior thereto the employer had not developed and implemented an energy control program for the maintenance shop, which adressed potential sources of energy which may include, but is not limited to, disconnecting the semi-truck battery before any maintenance is performed.     Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.215 B09

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch:    a) South wall of maintenance shop: On March 14, 2012 and at times prior thereto each of the adjustable tongue guards on the Dewalt bench grinder were 1 inch away from the grinding wheel.      Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B04 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material including reserve stocks of carbide and acetylene:    a) South east wall of trailer shop: On March 14, 2012 and at times prior thereto reserve cyclinders of oxygen and acetylene were stored together.  It was not known if these cylinders were empty or full.      Note) Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1)(i): The employer did not have a list of the hazardous chemicals known to be present and use an identity that is referenced on the appropriate material safety data sheet:    a) Maintenance shop: On March 14, 2012 and at times prior thereto the employer did not develop and maintain a list of chemicals currently used by employees in the maintenance shop.        Note) Abatement certification IS required for this item.