OSHA Inspection: DM INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DM INC. in 61 WILLET ST., PASSAIC, NJ 07055 (NAICS 238350). OSHA activity number 332826270.

Watch DM INC. — free Get an email when a new federal OSHA severe-injury report for DM INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DM INC.
Site address
61 WILLET ST.
City
PASSAIC
State
NJ
ZIP
07055
Mailing
61 WILLET ST., PASSAIC, NJ 07055
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
4
Ownership type
A

15 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.23(c)(1):  Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing.    a)  Woodworking Shop:  Employee, standing on a plywood platform to work on dust collector, did not have means of fall protection; thereby, was exposed to a fall hazard in excess of 15', on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.107 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1910.107(b)(1):  Spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry, and that aluminum or other substantial noncombustible material was not used for intermittent or low volume spraying.    a)  Spray Booth Room:  A spray booth partially constructed of sheetrock to which the walls were not securely supported, were used by employees when spraying combustible and flammable materials, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $2400

1910.107 B05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.107(b)(5)(i):   Visible gauges, audible alarm or pressure activated devices was not installed to indicate or insure that the required air velocity is maintained.     a)  Spray Booth Room:  Employer did not have a method or device to measure required air velocity during spray booth operations, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.107 C05

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.107(c)(5):  Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, and wiring was not in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.    a)  Spray Booth Room:  A flexible cord, passing through an opening in the ceiling over the spray booth used for combustible and flammable materials, was used to energize a non-enclosed, non-intrinsically safe, and non-approved fluorescent light fixture, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.107 G07

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $3000.00
29 CFR 1910.107(g)(7):   "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at the spraying area and the paint storage rooms.    a)  Spray Booth Room:  Combustible and flammable stains and finishers are used and stored in the spray booth room in which there is not one No Smoking sign present, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $3000

1910.212 A05

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1910.212(a)(5):   Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch.    a)  Woodworking Area:  An unguarded wall mounted exhaust fan was approximately 6' above floor surface, and approximately 3' above work bench area; thereby, exposing employees to a laceration hazard, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $2400

1910.213 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.213(c)(1):  Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut.     a)  Woodworking Shop:  The guard was removed from the Paoloni P300 circular saw; thereby, exposing employees to an amputation hazard, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.213 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(d)(1):   Each circular crosscut table saw was not guarded by a hood.    a)  Woodworking Shop:  The guard was removed from the Paoloni P300 circular saw; thereby, exposing employees to an amputation hazard, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $0

1910.213 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.213(c)(2):   Each hand-fed circular ripsaw was not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator.     a)  Woodworking Shop:  No spreader was used during ripsaw cuts on the Paoloni P300 circular saw; thereby, exposing employee to an amputation or struck-by hazard, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.213 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1910.213(c)(3):   Each hand-fed circular ripsaw was not provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.     a)  Woodworking Shop:  Nonkickback fingers or dogs were not used during ripsaw cuts on the Paoloni P300 circular saw; thereby, exposing employee to a struck-by hazard, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $2400

1910.303 B02

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.    a)  Woodworking Shop:  An electrical receptacle box was hanging freely and was not mounted and secured to prevent movement, on or about 3/6/2012.    b)  Woodworking Shop:  An electrical toggle switch box was hanging freely and was not mounted and secured to prevent movement, on or about 3/6/2012.    c)  Woodworking Shop:  Electrical receptacle boxes were mounted on a wooden movable work bench, or about 3/6/2012.    d)  Woodworking Shop:  An extension cord lying on the floor surface was made using a metal electric receptacle box, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $2400

1910.303 B07 I

Serious Gravity 10 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.303(b)(7)(i):   Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    a)  Woodworking Shop, Interior Wall Exit Side:  The knockout plug was missing from a junction box servicing 220V, on or about 3/6/2012.    b)  Woodworking Shop, Interior Wall Exit Side:  The knockout plug was missing from a junction box servicing 220V, on or about 3/6/2012.    c)  Woodworking Shop, Interior Wall Separating Spray Room:  The knockout plug was missing from a junction box servicing 110V, on or about 3/6/2012.    d)  Woodworking Shop, Interior Wall Separating Spray Room:  The knockout plug was missing from a receptacle box servicing 110V, on or about 3/6/2012.    e)  Woodworking Shop, Wood Post:  The knockout plug was missing from junction box servicing a 110V receptacle box, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.305 B02 I

Serious Gravity 10 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $4200.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.    a)  Woodworking Shop, Wood Beam:  The cover was missing from a junction box servicing 220V, on or about 3/6/2012.    b)  Spray Booth Room:  The cover was missing from a junction box servicing 220V, on or about 3/6/2012.    c)  Woodworking Shop, Wood Post:  The cover was missing from a junction box servicing 110V, on or about 3/6/2012.    d)  Woodworking Shop, Above Exit Door:  The cover was missing from a junction box servicing 110V, on or about 3/6/2012.    e)  Woodworking Shop, Elevated Platform:  The cover was missing from junction box servicing the Grizzly Dust Collector, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $4200

1910.305 G01 IV A

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $3000.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure.    a)  Spray Booth Room:  A flexible cord was permanently used to energize a fluorescent light mounted in the spray booth, on or about 3/6/2012.    b)  Woodworking Shop:  A flexible cord (extension cord) was permanently used to energize a Grizzly wood planer, on or about 3/6/2012.
Recent events (1)
  • — Z (S) $3000

1910.305 G02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $3000.00
29 CFR 1910.305(g)(2)(ii):   Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced.      a)  Woodworking Shop:  A junior-hard service cord no. 12 on a 220V Grizzly wood planer was spliced with a 110V flexible cord and did not  retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced, on or about 5/29/2012.
Recent events (1)
  • — Z (S) $3000

DM INC.

View DM INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332826270.