Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BREEZE NATIONAL INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BREEZE NATIONAL INC in 606 W 131ST STREET, NEW YORK, NY 10027 (NAICS 238990). OSHA activity number 332835693.

Watch Breeze National INC — free Get an email when a new federal OSHA severe-injury report for Breeze National INC is published. One employer, no account, unsubscribe in one click.
Establishment
BREEZE NATIONAL INC
Site address
606 W 131ST STREET
City
NEW YORK
State
NY
ZIP
10027
Mailing
31 BAY ST, BROOKLYN, NY 11231
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
75
Ownership type
A

2 citations on file for this inspection.

1926.858 D

Serious Gravity 10 1 instance 7 exposed
Issued
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1926.858(d):  During demolition operations the employer did not ensure that any structural member being dismembered shall not be overstressed:    a)  During demolition of the two story building on 3-21 a large crack developed in one of the three main steel beams (B girder) which support the 2fl.  The crack was at a weak point in the girder known as a splice connection which became overstressed when part of the girder was cut off.  Though the splice connection itself was not visible due to concrete encasing and was not shown on the demolition plan, the large crack was in plain view and the girder beam was visibly sagging in danger of collapse.  Employees were exposed to structural collapse hazard.      Location: 606 W 131 Street, New York, N.Y     On or about 3/22/2012       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — C (S) $4900
  • — F (S) $4900
  • — Z (S) $4900

1926.859 G

Serious Gravity 10 7 exposed
Issued
Penalty
Initial $4900.00 · Current $0.00 Reduced
29 CFR 1926.859(g):  The employer did not ensure that:  During demolition, continuing inspections by a competent person shall be made as the work progresses to detect hazards resulting from weakened or deteriorated floors, or walls, or loosened material.  No employee shall be permitted to work where such hazards exist until they are corrected by shoring, bracing, or other effective means:    a)  During demolition of the 2 story garage building:  The employer did not inspect and discover a large crack in the B girder which had developed on 3-21.  On 3-22 the employer cut the next beam (C girder) which had a similar spliced weak point, resulting that the 2nd floor collapsed.      Location: 606 W 131 Street, New York, N.Y     On or about 3/22/2012       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — C (S) $4900
  • — F (S) $0
  • — Z (S) $4900

View BREEZE NATIONAL INC's full OSHA safety record →