BREINIGSVILLE, PA —
OSHA Inspection: CC CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CC CONSTRUCTION INC in 37 GRIM ROAD, BREINIGSVILLE, PA 18031 (NAICS 236220). OSHA activity number 333291524.
Where did this inspection happen?
- Establishment
- CC CONSTRUCTION INC
- Site address
- 37 GRIM ROAD
- City
- BREINIGSVILLE
- State
- PA
- ZIP
- 18031
- Mailing
- 4210 FRITCH DRIVE, BETHLEHEM, PA 18020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 B02
- Issued
- Penalty
- Initial $2168.00 · Current $1626.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Main electrical supply room - On or about March 20, 2012, an energized 240 VAC electrical supply line was hanging by the conductors and lacked strain relief protection for the connection.
Recent events (2)
- — I (S) $1626
- — Z (S) $2168
1926.403 I02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. a) Electrical distribution room - On or about March 20, 2012, employees were working in the area of energized 240 VAC electrical panels without a factory dead front and door assembly installed. b) Facility wide - On or about March 20, 2012, employees were working in and around energized electrical receptacles without a cover plate installed. c) Facility wide - On or about March 20, 2012, employees were working in and around future receptacles with energized 110 VAC wires exposed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at CC CONSTRUCTION INC
MARION, MA—2020-06-29 00:00:00
CC CONSTRUCTION, INC.
DURAND, IL—2012-03-28 00:00:00
CC CONSTRUCTION, INC.
CHEYENNE, WY—2011-09-26 00:00:00
CC CONSTRUCTION INC.
PADUCAH, KY—2011-02-04 00:00:00
CC CONSTRUCTION, INC.
COAMO, PR—1996-01-18 00:00:00
CC CONSTRUCTION INC
View CC CONSTRUCTION INC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333291524.