Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: NY SKYLINE GENERAL CONSTRUCTION CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NY SKYLINE GENERAL CONSTRUCTION CORP in 601 W 190TH ST, NEW YORK, NY 10040 (NAICS 238140). OSHA activity number 333955821.

Watch NY Skyline General Construction Corp — free Get an email when a new federal OSHA severe-injury report for NY Skyline General Construction Corp is published. One employer, no account, unsubscribe in one click.
Site address
601 W 190TH ST
City
NEW YORK
State
NY
ZIP
10040
Mailing
114-13 101 AVENUE, SOUTH RICHMOND HILL, NY 11419
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.302 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.302(b)(2): Safety clips or retainers shall be securely installed and maintained on pneumatic impact (percussion) tools to prevent attachments from being accidentally expelled.    Location: 601 W. 190th St., New York, NY.    a) Employer failed to provide safety clips for an Airman PDS185S compressor that was being utilized to power pneumatic hammer drills; on or about 4/14/12.
Recent events (1)
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.404(b)(1)(i):  General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    Location: 601 W. 190th St., New York, NY.    a) Employer did not ensure that the Bosch hammer drill powered by an extension cord was provided with a GFCI or an assured equipment program; on or about 4/14/12.
Recent events (1)
  • — Z (S) $2000

View NY SKYLINE GENERAL CONSTRUCTION CORP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333955821.