Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CC RESIDENTIAL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CC RESIDENTIAL, LLC in 9850 CACHE BLVD., ENGLEWOOD, CO 80112 (NAICS 236116). OSHA activity number 334098027.

Watch CC Residential, LLC — free Get an email when a new federal OSHA severe-injury report for CC Residential, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CC RESIDENTIAL, LLC
Site address
9850 CACHE BLVD.
City
ENGLEWOOD
State
CO
ZIP
80112
Mailing
10 MANSELL COURT EAST SUITE 150, ROSWELL, GA 30076
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
16
Ownership type
A

3 citations on file for this inspection.

1926.1053 B16

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $1500.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:    a) On or about April 19, 2012, and at times prior, CC Residential, LLC, as controlling employer, did not ensure that  Westar Framing, Inc., Losaw Electric, Inc., T.D. Industries, Inc., Pearson Mechanical, Inc., and EZ Heating & AC, subcontractors, protected their employees from injury in that, employees were using job made ladders that had defects such as but not limited to, excessive cracks, inproperly inset rungs and incorrect blocking of rungs.    Abatement Note:  Abatement certification and documentation is required for this item (see enclosed "Certification of Correction Action Worksheet"). 29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:    (a) On or about April 19, 2012, and at times prior, CC Residential, LLC, as the controlling employer, did not ensure that Westar Framing, Inc., a subcontractor, protected their employees from injury in that, flexible cords were being run over by vehicles/forklifts.    Abatement Note:  Abatement certification and documentation is required for this item (see enclosed "Certification of Correction Action Worksheet").
Recent events (3)
  • — F (O) $1500
  • — C (S) $1020
  • — Z (S) $1020

1926.651 J02

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    a) On or about April 19, 2012, and at times prior, CC Residential, LLC, as controlling employer, did not ensure that  Q-3 Contracting, Inc., a subcontractor, protected their employees from injury in that, the spoil pile was within 2 feet of the edge of the trench.    Abatement Note:  Abatement certification and documentation is required for this item (see enclosed "Certification of Correction Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.1051 A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:      a) On or about April 19, 2012, and at times prior, CC Residential, LLC, as controlling employer, did not ensure that  Westar Framing, Inc., a subcontractor, protected their employees from injury in that, employees were using 4 pallets to gain access to the job trailer supply room.    Abatement Note:  Abatement certification and documentation is required for this item (see enclosed "Certification of Correction Action Worksheet").