PEARSALL, TX —
OSHA Inspection: BLACK CREEK WELL SERVICES, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLACK CREEK WELL SERVICES, LP in T.J. PEARSALL #1H WELL LONG: -99.10011, LAT: 28.81108, PEARSALL, TX 78061 (NAICS 213112). OSHA activity number 334221231.
Where did this inspection happen?
- Establishment
- BLACK CREEK WELL SERVICES, LP
- Site address
- T.J. PEARSALL #1H WELL LONG: -99.10011, LAT: 28.81108
- City
- PEARSALL
- State
- TX
- ZIP
- 78061
- Mailing
- 18615 TUSCANY STONE, STE 300, SAN ANTONIO, TX 78258
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1785.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards of entrapment due to not having a geronimo line to escape while working. Well site: On or about May 7, 2012, and at times prior thereto, in case of an emergency, an employee was exposed to the hazards of burns due not having a geronimo line installed.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $3570.00 · Current $2142.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides and railings were not provided with a toeboard where required: Service rig: On or about May 7, 2012, employees were exposed to a fall hazard of approximately 7 ft. in height from the rigs work platform approximately 8 ft. width x 9 ft. length to the unpaved ground level while operating a service rig during the reworking an oil/gas well.
Recent events (2)
- — I (S) $2142
- — Z (S) $3570
1910.176 B
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: Pipe storage area: On or about May 7, 2012, employees were exposed to being stuck by pipes, stored on a rack with no means of preventing pipes from rolling off, while the employees accessed the pipe rack.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Well head area: On or about May 7, 2012 employees were exposed to a caught in hazard from the swivel unit engine not having guards for the fan, alternator pulleys, and v belts while the employees used the swivel unit to drill out cement and set plugs in to reworking an oil/gas well.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) Well head area: On or about May 7, 2012 employees were exposed to a caught in hazard from the swivel unit engine not having guards for the fan, alternator pulleys, and v belts while the employees used the swivel unit to drill out cement and set plugs in to reworking an oil/gas well.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $595.00 · Current $357.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On the rig carrier vehicle: On or about May 7, 2012 employees were exposed to, in case of an emergency, not being able to respond to a fire with adequate equipment from a fire extinguisher that did not have an inspection tag. b) Well site near a rig anchor: On or about May 7, 2012 employees were exposed to, in case of an emergency, not being able to respond to a fire with adequate equipment from a fire extinguisher that did not have an inspection tag. c) Well site near a rig anchor: On or about May 7, 2012 employees were exposed to, in case of an emergency, not being able to respond to a fire with adequate equipment from a fire extinguisher that did not have a pin to prevent accidental discharge.
Recent events (2)
- — I (O) $357
- — Z (O) $595
More inspections at BLACK CREEK WELL SERVICES, LP
DILLEY, TX—2016-02-16 00:00:00
BLACK CREEK WELL SERVICES, LP
View BLACK CREEK WELL SERVICES, LP's full OSHA safety record →
More inspections in this industry (NAICS 213112)
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
GARDEN CITY, TX—2026-06-17
EBENEZER COMPANIES LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source