CROTON ON HUDSON, NY —
OSHA Inspection: MICHELLE CONSTRUCTION OF WESTCHESTER, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MICHELLE CONSTRUCTION OF WESTCHESTER, INC. in 383 SOUTH RIVERSIDE AVENUE CROTON-ON-HUDSON, CROTON ON HUDSON, NY 10520 (NAICS 236220). OSHA activity number 334281342.
Where did this inspection happen?
- Establishment
- MICHELLE CONSTRUCTION OF WESTCHESTER, INC.
- Site address
- 383 SOUTH RIVERSIDE AVENUE CROTON-ON-HUDSON
- City
- CROTON ON HUDSON
- State
- NY
- ZIP
- 10520
- Mailing
- 138 OAK STREET, PORT CHESTER, NY 10573
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 G01 VI
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). a) Employees hoisting materials from a scaffold platform 25 feet above the ground were not protected from falling as there was no mid rail. Observed on or about 04 May 2012. b) An employee was standing on an outrigger without fall protection. The outrigger was 25 Feet 8 inches above the ground. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $2000
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) Employees were not trained to recognize and control hazards associated with pipe scaffolds. 383 South Riverside Avenue, Croton-on-Hudson, New York. Facade of builiding. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Employee was nailing two two-by-four pieces of wood to the top of the parapet wall (24 inches) while standing just inside the wall, inches from the roof edge. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a) Employees did not receive adequate training on the hazards of fall protection or procedures to follow in minimizing those hazards. 383 South Riverside Avenue, Croton-on-Hudson, NY. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $0
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) Spoil pile was directly next to excavation and did not have sufficient clearance to prevent soil from falling back into excavation. Excavation was not protected from spoil pile by barriers or sloping. Rear of building under construction. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $2000
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. (a) Employees entered a 7 foot deep by 30 foot long excavation that was not inspected by a competent person for evidence of a situation that could have resulted in possible cave-ins, or indications of failure of protective systems. 383 South Riverside Avenue, Croton-on-Hudson, New York rear of building. Observed on or about 04 May 2012.
Recent events (1)
- — Z (S) $2800
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $500.00 · Current $500.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that that did not provide protective measures such as shoring, sloping or benching of the excavation. (a) Employees erected a scaffold in an unprotected excavation 7 feet deep by 30 feet long. 383 South Riverside Avenue, Croton-on-Hudson, rear of building. Observed an unprotected trench on or about 04 May 2012.
Recent events (1)
- — Z (S) $500
1926.1052 C01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Employees used stairwell from first to second floor with no handrails. Elevation from first level to second is 10 feet 10 and 3/4 inches. (b) Employees used stairwell from second floor to third floor with no handrails. Elevation from second level to third level is 9 feet 5 and 3/4 inches. (c) Employees used stairwell from first floor to basement with no handrails. Observed on or about 04 May 2012 at 383 South Riverside Avenue, Croton-on-Hudson, New York.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334281342.