PENSACOLA, FL —
OSHA Inspection: WARRINGTON UTILITY & EXCAVATING, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WARRINGTON UTILITY & EXCAVATING, INC in 7171 N DAVIS HIGHWAY, PENSACOLA, FL 32505 (NAICS 237110). OSHA activity number 334328911.
Where did this inspection happen?
- Establishment
- WARRINGTON UTILITY & EXCAVATING, INC
- Site address
- 7171 N DAVIS HIGHWAY
- City
- PENSACOLA
- State
- FL
- ZIP
- 32505
- Mailing
- 8401 UNTREINER AVE, PENSACOLA, FL 32534
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 18
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $1156.00 · Current $1156.00
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) 7171 N. Davis Highway Pensacola, FL 32505: On or about May 17, 2012 and at times prior to; the employer exposed his employees to falling or flying object hazard in that employees were allowed under an excavator with a suspended load while installing 14ft 8 inch diameter sewer pipes in a 9.5 ft trench excavation without a hardhat.
Recent events (2)
- — I (S) $1156
- — Z (S) $1156
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $1445.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) 7171 N. Davis Highway Pensacola, FL 32505: On or about May 17, 2012 and at times prior to; the employer exposed his employees to an engulfing/crushing hazard in that he allowed employees to access a trench excavation which measured 9.5 feet in depth and 25 feet in length without providing other safe means of egress.
Recent events (2)
- — I (S) $1000
- — Z (S) $1445
1926.651 D
- Issued
- Penalty
- Initial $867.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(d): Employees exposed to public vehicular traffic were not wearing warning vests provided by the employer: (a) 7171 N. Davis Highway Pensacola, FL 32505: On or about May 17, 2012 and at times prior to; the employer exposed his employees to a struck-by hazard in that he did not ensure employees who were installing 14 ft. 8 inch diameter sewer pipes in a 9.5 feet deep and 25 feet length trench excavation were not wearing warning vests while working near vehicular traffic.
Recent events (2)
- — I (O) $0
- — Z (S) $867
1926.651 E
- Issued
- Penalty
- Initial $1445.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(e): Employee was not prohibited to be underneath loads handled by lifting or digging equipment: (a) 7171 N Davis Highway Pensacola, FL 32505: On or about May 17, 2012 and at times prior to; the employer exposed his employees to a struck-by, crushing, and caught in between hazards in that employees were allowed to install 14 ft. 8 inch diameter sewer pipes in a 9.5 ft. deep trench while working under a excavator with suspended loads.
Recent events (2)
- — I (S) $0
- — Z (S) $1445
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $28000.00 · Current $17592.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the excavation was sloped at an angle steeper that one and one half horizontial to one vertical (34 degrees measured from the horizontal): (a) 7171 N. Davis Highway Pensacola, FL 32504: On or about May 17, 2012 and at times prior to; the employer exposed his employees to crushing/engulfing hazards in that employees were allowed to install 14 ft. 8 inch sewer pipes in a trench that was 9.5 feet in depth and 25 feet in length (class B soil) which had nearly vertical excavation walls that were not sloped back to the proper angle as required by the elements of Sloping/Benching options (2), (3), or (4).
Recent events (2)
- — I (W) $17592
- — Z (W) $28000
More inspections at WARRINGTON UTILITY & EXCAVATING, INC
PENSACOLA, FL—2019-08-29 00:00:00
WARRINGTON UTILITY & EXCAVATING, INC
View WARRINGTON UTILITY & EXCAVATING, INC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source