2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WIRECO WORLDGROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WIRECO WORLDGROUP in 609 NORTH 2ND STREET, SAINT JOSEPH, MO 64501 (NAICS 332618). OSHA activity number 334334513.

Watch Wireco Worldgroup — free Get an email when a new federal OSHA severe-injury report for Wireco Worldgroup is published. One employer, no account, unsubscribe in one click.
Establishment
WIRECO WORLDGROUP
Site address
609 NORTH 2ND STREET
City
SAINT JOSEPH
State
MO
ZIP
64501
Mailing
609 NORTH 2ND STREET, SAINT JOSEPH, MO 64501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
160
Ownership type
A

4 citations on file for this inspection.

1910.212 B

Deleted Serious Gravity 1 4 instances 10 exposed
Issued
Penalty
Initial $3000.00 · Current $0.00 Reduced
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On or about 12 Jun 12, and at times prior, employees were exposed to hazards in the Maintenance Addition of Building 10 resulting from a machines including, but not necessarily limited to, a DoALL brand vertical band saw and a Baldor brand bench grinder that were not securely anchored to prevent walking or moving.
Recent events (3)
  • — F (S) $0
  • — C (S) $3000
  • — Z (S) $3000

1910.219 D01

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $3000.00 · Current $1000.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about 12 Jun 2012, and at times prior, employees working in the Machine Shop were exposed to hazards resulting from unguarded pulleys and belts on a Curtis Manufacturing Company brand air compressor.
Recent events (3)
  • — F (O) $1000
  • — C (S) $3000
  • — Z (S) $3000

1910.303 G01

Deleted Serious Gravity 1 1 instance 12 exposed
Issued
Penalty
Initial $3000.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      On or about 12 Jun 2012, and at times prior, in the Maintenance Addition to Building 10, employees were exposed to electrical hazards resulting from a lack of sufficient access and working space about electrical equipment including, but not necessarily limited to, a 240 volt electrical panel used to control an Enerpac brand 100 ton hydraulic press.
Recent events (3)
  • — F (S) $0
  • — C (S) $3000
  • — Z (S) $3000

1910.305 B01 II

Other-than-serious 1 instance 12 exposed
Issued
Penalty
Initial $3000.00 · Current $1000.00 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about 12 Jun 2012, and at times prior, in the Maintenance Addition of Building 10, employees were exposed to electrical hazards resulting from unused openings in a 240 volt electrical box that were not effectively closed.
Recent events (3)
  • — F (O) $1000
  • — C (S) $3000
  • — Z (S) $3000

View WIRECO WORLDGROUP's full OSHA safety record →