Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAZEL & CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAZEL & CO. in 400 W. FIRST ST., ROCK FALLS, IL 61071 (NAICS 423510). OSHA activity number 334432812.

Watch Mazel & CO. — free Get an email when a new federal OSHA severe-injury report for Mazel & CO. is published. One employer, no account, unsubscribe in one click.
Establishment
MAZEL & CO.
Site address
400 W. FIRST ST.
City
ROCK FALLS
State
IL
ZIP
61071
Mailing
400 W. FIRST ST., ROCK FALLS, IL 61071
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
33
Ownership type
A

6 citations on file for this inspection.

1910.137 B02 VIII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2450.00 Reduced
Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-5 and I-6:    (a) Type 1 Class 0 White Rubber Co. rubber insulating gloves were not tested every six months after first issue. The gloves are used by the in-house electrician when performing voltage checks after powering down equipment and before performing work. On or about 5/29/2012 the gloves were used when troubleshooting and replacing the PC of machine #2 (230 volts).      Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.137 B02 XII

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.137(b)(2)(xii):     The employer did not certify that electrical protective equipment had been tested in accordance with the requirements of paragraphs (b)(2)(viii), (b)(2)(ix), and (b)(2)(xi) of this section:    (a) The Type 1 Class 0 White Rubber Co. gloves used by the in-house electrician have not been certified that they have been electrically tested.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1910.178(p)(1):     Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    On or about 5/30/2012,    (a) The horn on the Caterpillar 50 CN-786 forklift was not functioning, exposing the operator and employees in the southwest section of the building to struck-by hazards associated with a lack of ability to provide an audible warning and therefore safe operation of a forklift. The forklift was not removed from service despite the need for repair.    (b) The horn, brake lights, and head lights on the Yale 671383 forklift were not functioning, exposing the operator and employees in the northeast section of the building to struck-by hazards associated with a lack of ability to provide audible and visible warnings and therefore safe operation of a forklift. The forklift was not removed from service despite the need for repair.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.178 Q07

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7):     Industrial trucks were not examined before being placed in service:    (a) The employer did not develop and implement a pre-use daily check of its Caterpillar 50 CN-786 and Yale 671383 forklifts. This resulted in defective horns and lights which went unnoticed, exposing the operator and any employees working nearby to struck-by hazards associated with a lack of ability to provide audible and visible warnings and therefore safe operation of a forklift.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2450.00 Reduced
29 CFR 1910.335(a)(2)(i):     When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:    (a) A screwdriver and cutting tool used by the electrician in performing work are not insulated properly for electrical work and are not marked as being acceptable for electrical work.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.178 A06

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(a)(6):     The employer did not ensure that all nameplates or markings were maintained in a legible condition:    (a) The nameplates located adjacent to the driver's seat on the Caterpillar 50 CN-786 and Yale 671383 forklifts were illegible. Both were covered with grease and the nameplate on the Caterpillar 50 CN-786 had a sticker on it.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334432812.